5. PREPARATION: ASSEMBLY AND ELECTRICAL CONNECTION
A. Station Assembly
●
Attach the handpiece holder.
Remove the handpiece holder mounting
screw from the side of the station. Attach the
handpiece holder to the station. (Figure 1)
(The handpiece holder can be installed on
either the left or right side.)
B. Handpiece Assembly
NOTE:
The handpiece can be used with the provided vacuum
pipe control knob (L). (See figure 2.)
●
Using vacuum function operative nozzle
(see page 21.)
1. Attach the nozzle.
a. Extend the vacuum pipe using the
vacuum pipe control knob. (Figure 3)
b. Remove the inside screw (M3 × 5) of the
nozzle. (Figure 4)
c. Loosen the nozzle mounting screw. Pass
the vacuum pipe through the nozzle hole
and attach the nozzle. (Figure 5)
d. Tighten the nozzle mounting screw.
2. Attach the pad.
a. Attach the pad. (Figure 7)
b. Adjust the pad to an appropriate position.
Adjust the vacuum pipe so that the pipe
and pad protrude as little as possible.
CAUTION
The nozzle and pad will be heated at high
temperature. Cool them before replacement.
CAUTION
●
Vacuum pipe
Do not use excessive force.
When not using a nozzle, retract the vacuum pipe
to the shortest length. (Figure 6)
(Figure 1)
M3 × 5
(Figure 4)
(Figure2)
(Figure 3)
(Figure 5)
(Figure 6)
(Figure 7)
Mounting screw
CAUTION
●
Pad
The pad does not last indefinitely. When it becomes
deteriorated, replace it. Since exposure to high
temperatures causes it to deteriorate faster, Hakko
recommends it be cooled after use.