background image

6. MAINTENANCE

 (Continued)

● Pump

Turn off the tool, remove the power plug from the power outlet and wait until the unit has 

cooled completely.

1. Loosen the screws on the back of the pump cover and remove the pump cover.

2. Remove the fixing plate.

3.  Clean the valve plate, fixing plate and pump head with isopropyl alcohol. 

Align the notch on the pump head with the corresponding notch on the valve plate. 

Match the notch on the outside of the pump head with the one on the fixing plate.  

Mount the diaphragm so that it is smooth and taut.

● Replacing the heating element (heating core)

Turn off the tool, remove the power plug from the outlet and wait until the unit has cooled 

completely.

1.

  

Remove the nozzle and element cover assembly with the nozzle changing tool and remove 

the joint cover.

2. Loosen the screw at the back of the pump cover and remove the pump cover.

3.  Remove the 6 screws from the handpiece (including 2 screws at the flange) and carefully 

separate the housing.

4. Disconnect the heating element terminal and replace the heating element.

5. Assemble using the same procedure in reverse.

6. Calibrate the nozzle temperature.

Be sure to calibrate the nozzle temperature after replacing the heating element. Failure to do 

this may result in a heater temperature that is much higher or lower than the previous one, 

and can contribute to accelerated oxidation and/or wear of the nozzle, or premature failure of 

the heating element.

Fixing plate

Valve plate

Pump head

Diaphragm

Remove the 2 screws.

Remove the joint cover.

Flange

2 screws (Flange)

Be careful of the spring

 

when opening 

the tool to replace the heating element.

Terminal

Push

Содержание FR-301

Страница 1: ...mV Power supply 100V 98W 50 60Hz 110V 122W 50 60Hz 120V 140W 60Hz 220V 100W 50 60Hz 230V 110W 50 60Hz 240V 120W 50 60Hz Vacuum generator Diaphragm pump Vacuum pressure 81 kPa 610 mmHg Suction flow 11...

Страница 2: ...n supervision or instruction concerning use of the appliance in safe way and understand the hazards involved Children should be supervised to ensure that they do not play with the appliance Cleaning a...

Страница 3: ...y clean the nozzle heating element and replace the filter if necessary Do not remove the pump cover during use 1 Place the nozzle over the lead wire of the part to be desoldered and begin heating Be c...

Страница 4: ...in the heating element until the cleaning pin passes cleanly through the hole Cleaning drill optional The cleaning pin passes cleanly and completely through the hole 4 Temperature setting The tempera...

Страница 5: ...e filter Ceramic paper filter L Filter Pipe and related parts 1 A general guide to replacement part Use the table below as a general guide to replacement part Use only genuine HAKKO FR 301 replacement...

Страница 6: ...assembly with the nozzle changing tool and remove the joint cover 2 Loosen the screw at the back of the pump cover and remove the pump cover 3 Remove the 6 screws from the handpiece including 2 screws...

Страница 7: ...of your solder to the end of the nozzle When the iron temperature reaches the set temperature the LED lamp will flash 5 Use a soldering iron tip thermometer optional accessory to measure the temperatu...

Страница 8: ...03 in nozzle B1087 For 1 0 mm 0 04 in nozzle B1088 For 1 3 mm 0 05 in nozzle B1089 For 1 6 mm 0 06 in nozzle B5141 Cleaning drill For 0 6 mm 0 02 in nozzle B1302 For 0 8 mm 0 03 in nozzle B1303 For 1...

Страница 9: ...1 0 N61 03 1 8 0 8 N61 04 2 1 N61 05 2 3 1 3 N61 06 2 3 0 8 N61 07 2 5 1 N61 08 3 1 3 N61 09 3 1 6 N61 10 11 2 1 0 8 N61 11 3 4 8 1 2 8 N61 15 2 3 1 N61 12 11 2 6 1 3 N61 13 11 1 6 3 N61 14 11 4 5 8 N...

Страница 10: ...7 B5025 Power cord 3 wire cord American plug B5026 Power cord 3 wire cord Chinese plug B5027 Power cord 3 wire cord but no plug B5028 Power cord 3 wire cord European plug B5029 Power cord 3 wire cord...

Отзывы: