background image

5. INITIAL SETUP

 Iron holder

Assemble as shown:

Insert the holder assembly securely into
the Iron holder base.

 Connector cord

Pass the connector cord through the hole in the
heat resistant pad.

4

 Soldering station

1. Insert the connector cord into the receptacle

at the front of the station.

2. Plug the power cord into a grounded wall

socket. The FP-101 is protected against
electrostatic discharge and must be
grounded for full efficiency.

Receptacle

Push the connector in as far as 
it will go. When the plug clicks, 
it is fully inserted.

 Tip tray

Place spare tips in the tip tray.

Содержание FP-101

Страница 1: ...ntrol features unique to the FP 101 make it applicable to a broad range of soldering applications Please read this manual before operating the FP 101 Keep this manual readily accessible for reference...

Страница 2: ...nt panel indicate the heat range selected for the FP 101 6 5 650 F 343 C 7 0 700 F 371 C 7 5 750 F 399 C 8 0 800 F 427 C 9 F 5 C at idle temperature Power consumption Tip to ground resistance Tip to g...

Страница 3: ...o become wet or use it with wet hands Do not modify the FP 101 Use only genuine Hakko replacement parts Do not bend or damage the control card If the card does become damaged do not force the card int...

Страница 4: ...n Tip tray Tip cleaner Tip not included Receptacle Card slot The heat range selector button Auto power shutoff switch on the bottom front of the case FM 2021 Connector assembly Sleeve assembly 7 5 6 5...

Страница 5: ...pad 4 Soldering station 1 Insert the connector cord into the receptacle at the front of the station 2 Plug the power cord into a grounded wall socket The FP 101 is protected against electrostatic dis...

Страница 6: ...F 343 C 7 0 700 F 371 C 7 5 750 F 399 C 8 0 800 F 427 C The ranges are approximate values only the actual tip temperature depends upon tip geometry and mass These lights are indicators one must press...

Страница 7: ...ed with solder turn the wire until a clean surface is presented When changing the cleaning wire lift the case top vertically to prevent solder debris from falling out 7 PARAMETER SETTINGS Auto power s...

Страница 8: ...s not active Never allow the unit to idle at a high temperature for extended periods This will allow the tip to become oxidized Turn the power switch OFF If it is to be out of service for several hour...

Страница 9: ...Check the grounding line 1 Unplug the connection cord from the station 2 Measure the resistance value between Pin 2 and the tip 3 If the value exceeds 2 at room temperature perform the tip maintenanc...

Страница 10: ...e heat range indicator lamp will blink rapidly and the heater is shut down NOTE Only the FM 2021 is compatible with the FP 101 Heater terminal short circuit error Soldering iron error 7 5 6 5 8 0 7 0...

Страница 11: ...eakage Solder does not wet the tip CHECK Is the tip contaminated with oxide ACTION Remove the oxide see Tip maintenance on P 7 The tip temperature is too high CHECK Is the connection cord broken ACTIO...

Страница 12: ...iring board for switch Grounding plate Fuse Description with LED lens and shieding plate 120V with rubber foot 2A UL 2 1 3 3 5 4 9 8 7 6 Tapping screw 4 12 4 Tapping screw 3 12 1 Tapping screw 3 8 3 T...

Страница 13: ...rt Name Conversion kit Connector assembly Connector cover Sleeve assembly Sleeve assembly Sleeve assembly Tip Heat resistant pad Specifications is yellow Yellow Orange Blue Iron Holder 1 B2790 B2791 B...

Страница 14: ...3 0 1 6 7 5 3 0 R0 2 9 3 R0 2 7 9 T7 JL02 SHAPE 0 2RLB Bent T7 JS02 SHAPE 0 2RSSB Bent 0 37 0 31 60 12 1 T7 C1 SHAPE 1C Bevel 0 47 0 04 45 1 11 5 T7 BC1 SHAPE 1BC Bevel 0 45 0 04 1 45 11 5 T7 BCF1 SH...

Страница 15: ...12 19 5 0 77 20 9 0 82 0 4 T7 1008 SOP19 5 x 10 2 20 5 4 3 13 4 6 0 24 0 17 0 53 14 8 0 58 0 81 T7 1009 SOP13 4 x 20 5 14 8 9 7 5 5 13 6 0 54 8 5 0 33 0 22 0 38 0 58 T7 1201 PLCC13 6 x 8 5 11 5 11 5 5...

Страница 16: ...DUCTS INC 28920 N AVENUE WILLIAMS VALENCIA CA 91355 U S A TEL 661 294 0090 FAX 661 294 0096 Toll Free 800 88 HAKKO www hakkousa com 4 2 5 5 6 Sep 2003 MA01226JU030930 13 WIRING DIAGRAM AC TR RED BLK W...