6
C. Desoldering station
CAUTION
• Be sure to unplug the cord by holding the plug.
• Securely insert the connecting cable all the way into the jack.
●
The HAKKO FM-205 detects when the iron is
removed from the iron holder and sends this
data to the station via the connecting cable.
That data is then used for various functions.
●
Connection
1. Connect the power cord to the inlet on the
rear of the station.
(Connect the plug from the MODEL FM-2024
to the receptacle on the HAKKO FM-205.)
CAUTION
Connect the plug to the receptacle, aligning the tab on the
plug with the opening on the receptacle.
2. Put MODEL FM-2024 into the iron holder.
3. Connect the hose from the MODEL FM-2024
to the filter case cover on the HAKKO FM-205
Station.
4. Connect the station to the shop air supply/
compressor.
Use only filtered air to eliminate the probability
of dust, water, and oil content from fouling the
mechanism.
Adjust the pressure to 490 kPa (71 psi) with
the regulator while allowing air to flow by
pressing the button (or pulling the trigger) on
the handpiece.
CAUTION
If you attempt to adjust the pressure without allowing air
to flow, or if the tube size is not as specified, the suction
capability will decrease. Ensure that the regulator shows
less than 882 kPa (128 psi) when the trigger is turned OFF.
If pressure equal to or higher than this value is applied,
damage may result.
Jack to connecting cable
Connecting cable
Plug
projection
Push the plug in as far as it will go,
and try to remove it without pressing
the release pin. If it stays in the
receptacle it is properly seated.
Receptacle opening
FM-
2024
24V
-70W
Insert all the way to the base.
typical interconnection
CAUTION
Be sure to use an air filter. Foreign matter in the piping or
the air supply can jam the solenoid valve, causing a failure.
5. Plug the power cord into a grounded wall
socket.
Ensure that the power switch is OFF before
inserting the AC plug.
CAUTION
Be sure to ground this product as it is ESD safe by design.
6. Turn ON the power.
CAUTION
The HAKKO FM-205 does not function properly if the
power is turned on with the trigger pressed. Release the
trigger and then turn the power ON.
FM-
2024
24V
-70W
Joint
Threaded portion
outside diameter ø6mm
(ø0.24in.)
Tube
Use a tube with inner diameter of
4 mm (0.16 in.) minimum.
Use length of 3 m (9.8 ft.) maximum.
Regulator
Adjust to 490
kPa (71 psi)
Air filter
Removes foreign
matter, dust, oil
content, and
water content
Compressor
Station