5. OPERATION

Assembling, connection and 
operation

1. Iron holder

2. Connecting  and  replacing 

the filter pipe

Pull  the  back  holder  (A)  until  it 
locks,  then  insert  the  filter  pipe 
assembly with the opening to the 
nozzle side. Ensure that the outer 
surface of the filter pipe assembly 
is  even  with  the  handle  support. 
If the filter pipe assembly is tilted, 
a leak may occur.
To   r e p l a c e   t h e   f i l t e r   p i p e 
assembly,  press  back  holder 
unlock  button,  pull  the  back 
holder to lock it, change the filter 
pipe assembly, then lock the filter 
pipe assembly.
Replace  the  filter  pipe  assembly 
in the cartridge.

3. Attaching  and  replacing 

the nozzle

Insert  the  grip  fully  into  the 
nozzle  cartridge  as  shown  in 
the  illustration.  Once  the  nozzle 
cartridge  is  inserted,  it  is  locked 
automatically.
To  replace  the  nozzle  cartridge, 
insert the nozzle remover into the 
flange of the nozzle cartridge and 
pull.

Nozzle remover

Iron holder 
assembly

Iron holder

(A)

(B)

Attaching

Replacing

Push

CAUTION

The nozzle can be very hot. To attach or 
remove the nozzle cartridge, be sure to 
use the nozzle remover to preclude the 
possibility of breaking the grip or cartridge.

CAUTION

The surface of the filter pipe 
assembly may be very hot.

Содержание FM-2020

Страница 1: ...lder Control Box DCB which in turn connects to the soldering station of choice either FM 202 or FP 102 For detailed information on the FM 202 and the FP 102 soldering stations refer to the instruction...

Страница 2: ...or Ejector type Vacuum pressure max 93 kPa 700 mmHg 28 in Hg Suction flow 28 min Tip to ground potential 2 mV Applied air pressure 490 kPa 5 0 kgf cm2 when in use trigger or button is pressed Compress...

Страница 3: ...can reach a very high temperature and should be considered potentially dangerous Turn the power off while taking breaks and when finished using the unit Before replacing parts or storing the unit turn...

Страница 4: ...necting cord Connect to FM 202 or FP 102 MODEL FM 2024 Front holder Filter pipe assembly Replace as a cartridge Back holder Filter pipe lock button The filter pipe assembly will be locked until this b...

Страница 5: ...change the filter pipe assembly then lock the filter pipe assembly Replace the filter pipe assembly in the cartridge 3 Attaching and replacing the nozzle Insert the grip fully into the nozzle cartrid...

Страница 6: ...CB attach two rubber feet which come with the FP 102 to the bottom rear of the FP 102 to prevent the FP 102 from falling off 3 Connect the hose from the FM 2024 to the filter case cover on the DCB FM...

Страница 7: ...value is applied damage may result 5 Turn ON the power Ensure that the power switch is OFF before inserting the AC plug CAUTION Be sure to ground this product as it is ESD safe by design Turn the powe...

Страница 8: ...e to the straight grip To remove the handle slide down the button located on the rear of the handle to unlock it then slide the handle toward the back of the FM 2024 5 OPERATION FM 2024 24V 70W FM 202...

Страница 9: ...ere will be an idle period of 15 seconds before the ready alarm sounds This time is used to ensure more efficient suction For the FM 202 pressing the push button or pulling the trigger before the alar...

Страница 10: ...le and the backside of the P W B If this is difficult to do try slowly moving the lead with the nozzle If the lead moves the solder is melted Never move the lead by force If it doesn t move easily the...

Страница 11: ...ition of the solder plating on the nozzle tip Check visually if the nozzle was eroded CAUTION The inside hole and the surface of the nozzle is plated with a special alloy Should this alloy become erod...

Страница 12: ...to the suction pipe while turning it clockwise Then remove the accumulated debris Check and clean the front and back holder bushings If foreign matter gets stuck on the contact surface between the fro...

Страница 13: ...he resistance is larger than 0 or in any location replace the cord assembly 1 Measure the resistance between plug pin 2 and the nozzle end 2 If the resistance value exceeds 2 at room temperature perfo...

Страница 14: ...e cover by pulling it straight out DCB The filter is clogged with hardened flux Replace the ceramic paper filter DCB Fit the filter case cover in place After replacing the ceramic paper filter DCB pre...

Страница 15: ...of the cord assembly in Maintenance CHECK Is the nozzle cartridge fully inserted ACTION Fully insert the nozzle cartridge CHECK Is the cord assembly broken Is the heater sensor disconnected ACTION Re...

Страница 16: ...the low temperature alarm too low ACTION Increase the setting CHECK Is the nozzle cartridge for use with the FM 2024 ACTION Turn the power switch OFF press fit the nozzle for the FM 2024 then turn th...

Страница 17: ...filter pipe If the ceramic paper filter is stiff with absorbed flux replace the filter CHECK Is solder residue stuck on the contact surface between the front holder or the back holder bushing and the...

Страница 18: ...See FM2024 02 Desoldering tool 24V 70W A1511 Filter pipe assembly Set of 10 A1512 Front holder A1513 Back holder bushing B2872 Handle For gun configuration B2873 Cleaning drill For heating element B2...

Страница 19: ...B N1 06 Nozzle 0 02 in 0 6 mm 0 02 in 0 6 mm 0 07 in 1 9 mm N1 08 Nozzle 0 03 in 0 8 mm 0 03 in 0 8 mm 0 08 in 2 0 mm N1 10 Nozzle 0 04 in 1 0 mm 0 04 in 1 0 mm 0 09 in 2 2 mm N1 13 Nozzle 0 05 in 1 3...

Страница 20: ...it board Socket White Blue 2 3 1 Green Black Red White Brown DCB MODEL FM 2024 HEAD OFFICE 4 5 SHIOKUSA 2 CHOME NANIWA KU OSAKA 556 0024 JAPAN TEL 81 6 6561 3225 FAX 81 6 6561 8466 http www hakko com...

Отзывы: