background image

8

 

AUTO ZERO function

 AUTO ZERO function is necessary for measureing voltage (mV) and resistance (OHM).

Pressing the  

 button displays "counting": 0.0.0 

 0.0 

 0.

Wait until the normal display appears.

Correction values from AUTO ZERO are recorded in the main body. Even after the power is 

turned off, the correction values are still available in later measurement sessions.

 Before using this function, it is necessary to cancel the "

AUTO HOLD

" displays.

 

AUTO HOLD function

When the 

 button is pressed quickly (less than one second), "

AUTO

" will blink at the lower 

right of the LCD.

While "

AUTO

" is blinking, touch the soldering iron tip to the sensor. (temperature)

While "

AUTO

" is blinking, touch the soldering iron tip to the conductive plate.  (mV, OHM)

"

AUTO

" will stop blinking and stay lit after a certain amount of time, and the fixed 

measurement result will be displayed.

Even after the fixed result is displayed, applying the tip to the sensor or the conductive plate 

will enable the AUTO HOLD function to work again.

Each time the 

 button is pressed, the AUTO HOLD function toggles between ON and OFF.

The AUTO HOLD function does not assume the measurement by temperature probes such 

as the hot air.

 

Data send function (infrared)

Press the 

 button for longer than one second. 

Temperature data will be sent by infrared output 

from the upper part of the HAKKO FG-101B. The 

temperature display will blink during sending.

The temperature send function can send data only 

to machines capable of receiving the data.

Only fixed values can be sent.

 

 In order to send fixed values, the AUTO HOLD function or MAX HOLD function can be used 

for temperature measurements and the AUTO HOLD function can be used for voltage or 

resistance measurements.

Make sure the HAKKO FG-101B infrared output part is facing and within the reception range 

of the receiver. 

 

Count function

When a sensor detected a sudden temperature

rise more than 100 degrees Celsius, the value of 

the thermometry count Increases.

When resetting the count number, push the 

button and the 

 button for more than one 

second at the same time.

4. OPERATION(continued)

Temperature measurement count

受信部

受信範囲

赤外線出力部

赤外線出力方向

Receiver

Infrared output 
direction

Infrared output part

Receiving 

scope

Содержание FG101B-03

Страница 1: ...emperature leak voltage and ground resistance Please read the manual carefully before operating the HAKKO FG 101B Please keep this manual readily accessible for reference Instruction Manual SOLDERING...

Страница 2: ...TIONS AND NOTES 3 4 OPERATION 4 4 1 Initial setup 4 4 2 Measurement of tip temperature 5 4 3 Measurement of leak voltage 6 4 4 Measurement of resistance difference between tip and ground wire 7 4 5 Ex...

Страница 3: ...isplay contents 1 This alarm indicates sensor burnout If this alarm occurs replace the sensor 2 When the and buttons are held pressed simultaneously for a long time 1 sec or longer the count is reset...

Страница 4: ...nctions Temperature measurement count function 000 to 999 times Power consumption 100V 3 2W 100 110V 3 6W 120V 3 2W 220 240V 3 6W Outline dimensions 211 W 53 H 126 D mm Weight 0 95 kg Usable temperatu...

Страница 5: ...rning use of the appliance in safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Be...

Страница 6: ...will move toward the terminal 2 Attach the sensor with the slide pin moved toward the terminal 3 Attach the sensor having a red mark to the red colored terminal and the sensor having a blue mark to th...

Страница 7: ...When flux is stuck on the terminal wipe it off with alcohol Do not use thinner or benzin for wiping Read the values when the display temperature is stable CAUTION Do not measure the temperature by ap...

Страница 8: ...ed into the power receptacle the HAKKO FG 101B main body 2 Wait until the tip reaches the set temperature If the soldering iron temperature is variable set temperature to maximum 3 Press the SELECT bu...

Страница 9: ...the button will be displayed Pressed for a long time 1 second or longer The MAX HOLD function will be released and the product will return to normal display CAUTION Turning off the power always cance...

Страница 10: ...Each time the button is pressed the AUTO HOLD function toggles between ON and OFF The AUTO HOLD function does not assume the measurement by temperature probes such as the hot air Data send function in...

Страница 11: ...performed smoothly using the functions of connected stations Ground terminal GND When using a type of soldering iron that is grounded with an alligator clip connect the clip to the GND terminal Maint...

Страница 12: ...r cord 3 core BS plug India B2424 Power cord 3 core European plug 220V KC 230V CE B2425 Power cord 3 core BS plug 230V CE U K B2426 Power cord 3 core Australian plug B2436 Power cord 3 core Chinese pl...

Отзывы: