① Power Lamp
It lights on by power breaker "ON".
② Stop Key
To stop hot wind generator.
Pushing "stop key" during a Hot Air Generator
being working on, count of delay timer starts
and a Hot Air Generator stops after finishing
timer count up.
③ Wind Fan Key
To operate wind fan.
Pushing "wind fan key" during a Hot Air Generator
being working on, count of delay timer starts and a
Hot Air Generator continues operation after finish-
ing timer count up.
④ Hot Wind Fan Key
To operate hot wind fan.
⑤ Timer Operation Key
To operate hot wind fan after passing setting
time.
⑥ Timer Stop Key
To stop operation of hot wind fan after passing
setting time, hot wind fan will stop. after finish-
ing two minutes operation of wind fan by delay
timer.
⑦ Wind Fan Lamp
To light on during wind fan operation.
Wind fan lamp will go on and off only when
10
《CONTROLLER 》
電 源
タイマー
遅延タイマー
送 風
外部制御
熱 風
異 常
タイマーリセット
停止
送風
熱風
設定
運転モード
モード切換え
タイマー運転
タイマー停止
℃
時.分
Hz
℃
熱風温度(PV)
温度設定(SV)/周波数/時間
送風機異常
出力
出力
オーバーヒート
出力1
温度調節異常 温度調節異常
出力2
外部過昇異常
入力
入力
熱電対2
入力
外部温調入力
−
+
−
外部送風
入力
外部熱風
入力
外部制御端子 使用上のご注意
①配線は、熱風発生機本体の電源ブレーカーを遮断して行ってください。
②運転中は、端子台カバーを外さないでください。
③配線材は、シールド線を使用してください。
④外部送風入力および外部熱風入力端子には、無電圧接点を接続してください。
⑤外部温調入力端子には、お客様の温度調節器の制御出力(電圧パルス出力DC12V)
を入力してください。
⑥取扱説明書の記載内容に従い、仕様を御理解いただいた上で、ご使用ください。
+
①
⑬
⑭
⑯
⑮
②
⑰
⑨
⑫
⑩
⑦
⑧
⑪
⑤
③
⑥
④
wind fan operation stops after finishing count
up delay timer, during delay timer working.
⑧ Hot Wind Lamp
To light on during hot wind fan working.
⑨ Timer Lamp
It lights on and off during timer being working
on or timer being counting during timer being
stopping.
⑩ Delay Timer Lamp
It lights on and off during delay timer being
counting.
⑪ Outer Control Lamp
It lights on when input of outer control(outer
wind fan, outer hot wind fan and outer temper-
ature control) is set.
⑫ Lamp For Irregularity
It lights on at irregularity occurrence.
⑬ Display for Present Value
It shows temperature measured at operation
mode.
It shows codes of mode, such as frequency set-
ting mode, timer setting mode or remaining time
of timer mode.
It lights on with power breaker "ON".
⑭ Setting Value Display
It shows setting temperature at operation mode.
It shows setting value of frequency at frequen-
cy setting mode. (only for HAP2000F、
HAP2000Tseries)
It shows timer setting value at timer setting
mode.
It shows error code at irregularity occurrence.
It lights on with power breaker "ON".
⑮ Data Alteration Key
It alters each setting value.
⑯ Mode Changing Key
It changes modes in order such as operation
mode, frequency setting mode(only for inverter
equipped type), timer setting mode, remaining
time of timer mode and mode of thermocouple
monitor for warning.
⑰ Outer Control Terminal Cover
This is outer control terminal cover. Removing a
cover, you will see outer control terminal. Please
refer to P19 for more details about outer control
terminal.
《 CONTROLLER 》