TFL-B202Q horizontal face plate option 

 

      Red or Green Display  

• Smart 4 digit meters, tricolor and mono-color bargraphs

• Front-panel digital scaling, offset, and setpoints

• Bargraph can be independently scaled to a sensitivity of 100 

counts full scale within any portion of the digital scale

• Over 38 different I-Series Input Signal Conditioners. For more 

info, please refer to the “I-Series Input Signal Conditioning 

Modules” catalog.

• 24 V DC excitation is available to power external 4-20 mA trans-

mitters and 5 or 10 V DC excitation is available for resistance 

bridge type sensors

• Dual 10 &  5-amp relays, 4 relays total plus 16-bit analog output

• 1/16 DIN meters have one 10 Amp relay or two 5 Amp relays plus 

16-bit analog output or an extra 5 Amp relay

• Auto-sensing AC/DC, wide range power supplies, 85-265 V AC / 

95-370 V DC or 18-36 V AC / 9-60 V DC 

• Quick, easy mounting into any panel thickness

• Direct flush mount into mosaic panels

• Optional metal surround case for DL and FL meters. 

• Standard plug-in screw terminal connectors are provided

6

TFL-B202Q 

 

Red or Green Display 

 

OMI 220 FAMILY FEATURES

6

TFL-B101Q

  

  Red or Green Display for Left, Right 

Tri-Color option for Center Bar only

6

TFL-B101D40 

 

Programmable Tri Color  

        or Mono Color, Red or Green Display

OMI 220 Family Bargraphs and Meters

9/64 DIN 36x144 mm (1.42”x5.69”)

100

0

10

30

50

70

90

20

40

60

80

Zero 

O/P

Span

SP1

SP2

SP3

SP4

Zero

Span

100

0

10

30

50

70

90

20

40

60

80

Zero

Span

SP1

SP2

SP3

SP4

100

0

10

30

50

70

90

20

40

60

80

Zero

Span

SP1

SP2

SP3

SP4

Smart, Programmable Bargraph Relays with Isolated 16 Bit 4-20 mA or 0-10 V Outputs

Содержание TFL-B101Q

Страница 1: ...ly AC DC Auto sensing wide range supply PS1 std 85 265 VAC 95 370 VDC 2 5W max 4 2W PS2 15 48 VAC 10 72 VDC 2 5W max 4 2W Operating Temp 0 to 60 C Storage Temp 20 C to 70 C Relative Humidity 95 non co...

Страница 2: ...dia grams are used to visually assist in following programming steps The following symbols are used to represent the functions and displays of the meter When two fingers are shown side by side the tw...

Страница 3: ...side the bar display area and by an OFF segment inside the bar display area Horizontal or Reverse Mounting Meters can be mounted horizontally in the panel and for those applica tions that require an o...

Страница 4: ...driver to release two plastic catches on either side of the case and levering backwards Step 4 Starting with the top first insert a small flat bladed screw driver and carefully lever the plastic catc...

Страница 5: ...the Scaling by pressing the ZERO and SPAN buttons simultaneously for two seconds Both scaling memories will be erased and an internal default scale factor will be loaded This provides a display of zer...

Страница 6: ...libration of the meter it is best to start with a reset of the scaling STEP C RESET THE SCALING ON CHANNEL ONE 1 Apply power to the meter and press the CH1 ZERO and CH1 SPAN buttons simultaneously for...

Страница 7: ...e Display Driver Board See the layout diagram on Page 4 and 14 for the exact location The steps to setup the setpoints are as follows 1 SELECT THE RELAY ACTIVATION MODE FOR EACH INSTALLED RELAY Make s...

Страница 8: ...ity as to the signal status especially just after transitioning to a new zone However if two or more setpoints with differently specified colors are positioned at the same set point value the color sp...

Страница 9: ...t the analog output as measured on the external multimeter to be the required value 20mA in this example When the HI button is pressed the UP or DOWN indicator LED shows the direction of change Releas...

Страница 10: ...s 23 and 24 have a unique plug and socket outline to prevent cross connection The main board uses standard right angled connectors Replacement 2 3 and 4 pin plug connectors are available see Accessori...

Страница 11: ...EXC Display Board Front SP1 SP2 SP3 SP4 Zero Span 0 10 20 30 40 50 60 70 80 90 100 Display Board Front SP1 SP2 SP3 SP4 Zero Span 0 10 20 30 40 50 60 70 80 90 100 Zero SP4 SP3 SP2 SP1 100 0 10 30 50 70...

Страница 12: ...ated I Series input modules that have span or zero potentiometers can be interchanged between any I Series com patible meter without recalibration because all of the analog scaling and reference circu...

Страница 13: ...fset 0 _ Increase Span Decrease 141E I Series Input Signal Conditioning Modules IF02 Line Frequency SPAN ZERO Frequency to Voltage Conversion 60 to 500VAC 269D IA12 AC Millivolt RMS Sigma Delta 371A A...

Страница 14: ...re IS02 Pressure Load Cell 5 10VDC Exc 20 2mV V 4 6 wire 2 20 mV V 10V 5V 4W 6W EXC Pressure Transducer PRESSURE 151A IR03 Linear Potentiometer 1K min POTENTIOMETER 1K Minimum Digital Scaling Input Ex...

Страница 15: ...tting Right angled Connector 6mm 0 24 10mm 0 39 26 5mm 1 05 Push On Connector for FI series IO board The adapter snaps on the 36x144 mm 1 42 x5 69 case and enables single unit or stack mounting in an...

Страница 16: ...ader position 4 3 2 1 1 2 3 4 5 75 Turn Potentiometer 0 Equivalent Circuit Increase Zero Decrease 5 4 3 2 1 Decrease Zero Increase 1 2 3 4 5 75 Turn Potentiometer 0 Zero Pot Disabled SPAN Turn Clockwi...

Страница 17: ...have one 10 Amp relay or two 5 Amp relays plus 16 bit analog output or an extra 5 Amp relay Auto sensing AC DC wide range power supplies 85 265 V AC 95 370 V DC or 18 36 V AC 9 60 V DC Quick easy mou...

Страница 18: ...HAKARU PLUS CORPORATION Tel 81 6 6300 2195 Page 18 05 12 16 TFL B101Q DS FL6 Space...

Страница 19: ...40 40 30 35 25 20 0 5 10 15 9x5 45 45 40 30 35 25 20 0 5 10 15 10x5 50 50 45 40 30 35 25 20 0 5 10 15 12 15 0 3 6 9 1 10 100 1000 1 5 15 150 1500 2 20 200 2000 2 5 25 250 2500 3 30 300 3000 4 40 400 4...

Страница 20: ...e IS05 Pressure Load Cell 20 2mV V 5 10V Exc 4 wire IS06 Pressure Load Cell Ext Exc 20 2mV V 4 wire IS07 Pressure 20 2mV V with High Impedance and External Excitation IT03 RTD 100 Pt 2 3 4 wire 200 to...

Отзывы: