Order h49 7144.907-333
6. Check the movement of all coupling sliders. When
screwing in the screw plug, all coupling sliders must
move outwards automatically.
Size of the basic clamping
device
Minimum dimension
𝒀 [𝒎𝒎]
42
3.5
52
8.7
65
5.3
80
6.8
100
9.7
125
16.7
Table 9:
Minimum size
𝑌
of the coupling slider
7. Check the test dimension
𝑌
on all coupling sliders. Once
the screw plug is fully screwed in, do not go below the
minimum dimension
𝑌
[see table for minimum dimension
𝑌
of the coupling sliders].