MANDO Adapt T212
Installation
Order h49 7144.907-333
59
WARNING
Serious injuries caused by the coupling ring being
ejected centrifugally after incorrect installation!
The coupling ring must never be installed without
the rotary extractor sleeve / the workpiece end-
stop.
If installation / removal work is interrupted, either
remove the coupling ring [rotary extractor sleeve
/ workpiece end-stop is not fully installed], or the
rotary extractor sleeve / the workpiece end-stop
must be fully installed before the interruption.
INFORMATION
Depending on size, positioning marks can be applied
to the coupling ring and the product.
6. Place the coupling ring around the coupling on the prod-
uct and the segmented clamping bushing so that the
pins in the product are aligned with the bores in the cou-
pling ring, paying attention to the marks if necessary. For
this, the coupling ring must engage in the groove in the
coupling and the segmented clamping bushing. Keep
the coupling ring closed.