B-Top
Commissioning
Order h49 7144.907-333
65
NOTE
Damage to components caused by cooling lubri-
cants with sufficient levels of corrosion inhibitor!
The components made of steel materials must be
protected before the usual oxidation process.
Only ever use cooling lubricants with sufficient
levels of corrosion inhibitor.
NOTE
Damage to materials caused by contaminated /
unprocessed cooling lubricants!
For the product to function properly, in particular
for internal flushing with cooling lubricants and/or
when using tools with internal flushing, ensure
that the cooling lubricant is cleaned / processed,
and that it contains no particles measuring >100
microns [filtered with a mesh width of 100 mi-
crons].
NOTE
Damage to seals caused by using the wrong cool-
ant lubricants!
To clean the product, never use a cooling lubri-
cant that attacks and damages the sealing ele-
ments installed. Those installed sealing elements
can be made of NBR, Viton and PUR materials.
Never use cooling lubricants that contain ester or
a polar solvent.
8.2 Checking the total stroke
WARNING
Serious crushing injuries caused by moving parts
when stroke positions are being tested!
Set the machine into set-up mode.
Reduce the operating pressure to a minimum.
Never reach into moving parts.
Pay attention to the gap dimensions of moving
parts.
Prior to commissioning, check the complete stroke to ensure
that there is sufficient reserve stroke and opening stroke.
For this, the same measurement of the moving part must be
performed at fixed points in release position and in clamping
reserve position.
Then deduct the value obtained in the clamping reserve po-
sition from the value obtained from the release position. This