light shoud be off for 5 seconds.
b) For the units’ malfunctins Annex 1
If there’s malfunction with the units, this will not affect the run of the complete appliance, but this
can be displayed by the malfunction light, the light flashing frequency is 0.5HZ, the number of
times is according to the malfunction table of the indoor units. When a round of flashing is
finished, the light shoud be off for 10 seconds. Then report according to the order : unit A unit B
unit C unit D, that is, if there’s malfunction with several units, then just report the indoor unit
with the highest priority level. Among the unit malfunctions, the priority level of the
communication malfunction is the highest, for others, that appears first will have the priority.
Remarks: in 3 minutes when the compressor stops, the units’ malfunctions are not displayed;
the complete appliance’s malfunctions are prior to the units’ malfunctions.
Annex 1 Malfunction codes of the whole unit
Remarks: under the mode of refrigeration, the malfunctions of each unit’s thin pipe temperature
sensor are not reported, under the mode of heating, the malfunctions of each unit’s thick pipe
temperature sensor are not reported.
F12
1
Outdoor EEPROM error
F1
2
The protection of IPM
F22
3
Overcurrent protection of AC electricity for the outdoor model
F3
4
Communication fault between the IPM and outdoor PCB
F19
6
Power voltage is too high or low
F4
8
Overheat protection for exhaust temperature
F21
10
Frost-removing temperature sensor failure
F6
12
Ambient temperature sensor failure
F25
13
Exhaust temperature sensor failure
E7
15
Communication fault between indoor and outdoor units
F11
18
deviate from the normal for the compressor
----
19
Loop of the station detect error
E9
21
High work-intense protection
---
24
Overcurrent of the compressor
---
25
Overcurrent protection for single-phase of the compressor
----
36
The socket protect
Functions and control
Domestic air conditioner
22
Содержание Z/N-Series
Страница 11: ... Pinping diagrams Domestic air conditioner 4ˊPinping diagrams 9 ...
Страница 12: ... Operation range Domestic air conditioner 5ˊOperation range 10 ...
Страница 15: ...CN9 CN10 CN36 CN3 CN23 CN24 CN25 CN28 PCB 1 Wiring diagram Domestic air conditioner 13 ...
Страница 16: ...PCB 2 CN1 CN5 CN6 CN7 CN10 CN11 CN8 CN9 CN4 CN3 CN2 Wiring diagram Domestic air conditioner 14 ...
Страница 17: ...Wiring diagram Domestic air conditioner 15 ...
Страница 33: ...Dimensinal drawings Domestic air conditioner 8 Dimensional drawings 9 Center of gravity Outdoor unit 31 ...
Страница 36: ...WARNING CAUTION Installations Domestic air conditioner 34 ...
Страница 37: ...Installations Domestic air conditioner 35 ...
Страница 38: ...Installations Domestic air conditioner 36 ...
Страница 39: ...Installations Domestic air conditioner 37 ...
Страница 40: ...Installations Domestic air conditioner 38 ...
Страница 41: ...Installations Domestic air conditioner 39 ...
Страница 42: ...Installations Domestic air conditioner 40 ...
Страница 45: ...Pressurize for over 3 minutes at 4 2MPa After above Installations Domestic air conditioner 43 ...