The first site of dip switch in YR-E06 is used to distinguish diferent types, ON:H MRV or
Fixed frequence types, OFF:Single split inverter. Their diagnostic codes are different.
ON
OFF
Normal state
--
--
Indoor ambient temp. sensor error
E1
F1
Indoor pipe temp. sensor error
E2
F2
Indoor pipe is over-heat in heating mode
F4
F4
Indoor pipe is in anti-freezing function in cooling
F5
F5
Communication error between indoor and outdoor units
E9
E3
Communication error between indoor and wired controller
E8
F7
Outdoor power model error
E0
E1
Outdoor current is too low
F2
E2
Compressor is over-heat
F6
E4
CT current is over high/one phase of power line is lost
E5
E5
Outdoor ambient temp. sensor error
E3
E6
Outdoor pipe temp. sensor 1 error
E4
E7
The voltage is over-high or over-low
E7
E10
Outdoor high or low pressure error
E6
E13
Outdoor pipe temp. sensor 2 error
E15
E15
The indoor pipe sensor temp. is too high
E12
E12
Outdoor pipe temp. sensor 3 error
E14
E14
Outdoor suction temp. sensor error
E13
E11
Compressor temp. sensor error
F7
E9
Indoor mid-evaporator temp. sensor error
F3
F3
Indoor PCB error
F8
E8
Water outlet system problem
E0
F6
Power lines is in wrong connection turn or one phase is lost
E10
F0
Humidity sensor error
E11
F8
Error Discription
SW1-1