Haier YR-E06 Скачать руководство пользователя страница 6

AUTO

RESET

LOCK

SLEEP

FAN

TEMP

ON

OFF

SWING

MODE

CLOCK

CODE

LIGHT

A
U
T
O

A
U
T
O

A
U
T
O

5

Use COOL in summer.Use HEAT in winter.
Use DRY in spring,autumn and in damp climate.

(1) Unit start

(2) Select operation mode

(3) Select temp. setting

Press ON/OFF button, unit starts.
Previous operation status appears on display
(Not Timer setting). Power indicator lights up.

Press MODE button. For each press, operation
mode changes as follows:

Unit will run in operation mode displayed on LCD.Stop display at your desired mode.

Every time the button is pressed, temp. setting
increases 1 C.
If  button is kept depressed, temp.setting will
increase quickly.
Every time the button is pressed, temp. setting
decreases 1 C.
If button is kept depressed, temp. setting will
decrease quickly.

Recommendations

(4) Fan speed selection

Unit will start running to reach the temp. setting
on LCD.

Press TEMP button

Auto running: During the Auto running mode, air conditioning running and can auto-select the cooling,
heating, fan mode according to the room temperature.
Fan running: The AC only have air supply running no cooling and heating running at the condition, AC
can't have auto air supply running, and can't display the setting temperature value on the LCD.
During the heating running, after start the AC, in order to prevent cooled air, AC can stop for a while be-
fore send heat air.
During the dehumification running, when the room temp.  setting temp. , not setting condition according
 to the air speed.

AUTO

MODE

FAN

HEALTH

TEMP

CLOCK

SET

TIMER

SLEEP

RESET

ON/OFF

AM

SWING

Hints

Wire controller can memorize each operation
status.
When starting it next time, just press ON/OFF
button and unit will run in previous status.

Press FAN button. For each press,
fan speed changes as follows:

Unit runs at the speed displayed on LCD.In HEAT
mode, warm air will blow out after a short period
of time due to cold-draft prevention function.
In DRY mode, when room temp. becomes 2 C
higher than temp. setting,  unit will run intermitte-
ntly at LOW speed regardless of FAN setting.

Press ON/OFF button.
Only time and room temp remains on LCD.
All indicators go out.
Vertical flap closes automatically.

(5) Unit stop

Remote controller

LOW

MID

HIGH

AUTO

Wire controller

FRESH

HIGH/SO

TIMER

SET

FILTER

A

HEALTH

1

5

4

Operation

The function of code B

AUTO

COOL

DRY

FAN

HEAT

The function of code A

COOL

DRY

HEAT

LOW

MID

HIGH

AUTO

The function of code A

The function of code B

LOW

MID

HIGH

AUTO

FILTER RESET

HEAT

HEAT

6

Hints:

Set Clock correctly before starting Timer operation.

You can let unit start or stop automatically at following  time: Before
you wake up in the morning, or get back from outside or after you
 fall asleep at night.

Operation mode will be displayed
on LCD.Power indicator lights up.

(2)TIMER mode selection

Press TIMER button to change
TIMER mode.Every time the
button is pressed, display
changes as follows:

TIMER ON/OFF

Wire controller possesses memory function, when use TIMER mode next time, just
press SET button after mode selecting if timer setting is the same as previous one.

(1)After unit start, select your
desired operation mode.

Please close health function first before setting  Timer, then you can do the TIMER ON
operation.Please do not use the health function when in TIMER ON state.

Wire remote controller or remote controller can memorize each working condition. Next time
open the unit, only need to press the ON/OFF key, the AC can work according to last time
working condition.(Timing, Sleeping and Swing mode not included.)

From Timing close to timing open, can setting sleep mode.

ON

MODE

FAN

HEALTH

TEMP

CLOCK

SET

TIMER

SLEEP

RESET

FILTER RESET

ON/OFF

AM

AM

1

SET

3

4

2

SWING

Operation

Select your desired TIMER mode (ON or OFF)

(3)Timer setting

Press TIME                 button.

Every time the button is pressed, time increases 10min.If button is kept
depressed, time will change quickly.
Every time the button is pressed, time decreases 10min.If button is kept depressed,
time will change quickly.
Time will be shown on LCD. It can be adjusted within 24hours.

(4)Confirming your setting

After setting correct time, press SET button to confirm "ON" or "OFF" stops flashing.
Time displayed: Unit starts or stops at x hour x min (ON or OFF). Timer mode indicator lights up.

To cancel TIMER mode

Just press TIMER button several times until TIMER mode disappears.

According to the seting timing open, close sequence, can realize first open then colse the unit or first
close then open the unit.

The function of code B

The function of code A

blank

ON

OFF

ON

OFF

blank

ON

OFF

HEAT

FRESH

HIGH/SO

TIMER

SET

FILTER

A

HEALTH

RESET

LOCK

SLEEP

FAN

TEMP

ON

OFF

SWING

MODE

CLOCK

CODE

LIGHT

1

4

HEAT

5

1

3

2

4

Содержание YR-E06

Страница 1: ...rmed Hint 1 Power supply switch and signal wire should be prepaired by the user 2 Don t touch PCB with hand Be careful not to hold down the wiring 1 Remove upper cover of wire controller Remove upper part of wire controller by press Lower cover of wire controller Upper cover of wire controller 2 Install the wired remote controller Please drill two holes on the wall according to the back cover scre...

Страница 2: ...l window of the remote control receiver 2 Series remote controller units please press the botton CODE to choose the program of code B 3 Series remote control units have not power failure compensation fig 2 FRESH HIGH SO TIMER SET FILTER B A M D HEALTH FRESH HIGH SO TIMER SET FILTER B A M D HEALTH Parts and Functions HEAT HEAT HEAT HEAT SET ROOM MODE FAN TEMP CLOCK SET TIMER SLEEP RESET FILTER RESE...

Страница 3: ... the Switch On Off button after the power comes again If the controller no sleep key use the swing key instead the sleeping on setting the auto restart function After the Auto restart is set if power failure suddenly occurs while the air conditioner is working it will resume the previous working state when the power is supplied again Used to adjust the time of timer and clock When the wire control...

Страница 4: ... TIMER SET FILTER B A M D HEALTH RESET LOCK SLEEP FAN TEMP ON OFF SWING MODE CLOCK CODE LIGHT OFF A U T O 25 26 21 23 17 15 18 19 22 24 27 20 14 16 36 1 2 3 4 6 7 9 10 5 8 34 33 28 32 31 30 35 29 The function of code A Used to select TIMER mode TIMER ON TIMER OFF The function of code B 8 5 2 16 28 30 33 29 14 11 17 21 24 HEAT 13 37 12 11 HEAT COOL DRY 8 At night before going to bed you can press d...

Страница 5: ...it stops at X hour X min According to the Time setting sequence of TIMER ON or TIMER OFF either Start Stop or Stop Start can be achieved 1 After unit start select your desired operation mode 2 Press TIMER button to change TIMER mode ON OFF Operation The function of code A TIMER ON OFF FRESH HIGH SO TIMER SET FILTER A HEALTH 1 HEAT MODE FAN HEALTH TEMP CLOCK SET TIMER SLEEP RESET FILTER RESET ON OF...

Страница 6: ...H SO TIMER SET FILTER A HEALTH 1 5 4 Operation The function of code B AUTO COOL DRY FAN HEAT The function of code A COOL DRY HEAT LOW MID HIGH AUTO The function of code A The function of code B LOW MID HIGH AUTO FILTERRESET HEAT HEAT 6 Hints Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following time Before you wake up in the morning or get ba...