Haier YR-E06 Скачать руководство пользователя страница 4

15.SET Button

Used to confirm TIMER and CLOCK settings when
heating or cooling.

3

Parts and Functions

Remote controller

1.TEMP Setting Button

(Used to set temperature. Setting ranges:
16 C to 30 C)

2.SWING Button

If you press this button once, auto swing will be
activated.
If you press this button again, the louver will fix
in the present position.

3.Power ON/OFF Button
    

Used for unit start and stop

After power on, the LCD of remote controller will
display the previous operation state (except for
TIMER,SLEEP and SWING state).

4.Operation MODE

Used to select operation mode.

Every time you press MODE button, operation mode
changes according to following sequence:

The function of code A

6.CLOCK Button

Used to set correct time.

7.TIMER Button

Used to select TIMER mode:TIMER
ON,TIMER OFF, TIMER ON/OFF.

(Note: if time of TIMER ON is the same as TIMER OFF,TIMER
ON/OFF cannot be set)

10.RESET Button

Press this button by using a sharp article to resume the
correct operation of the remote controller in case of need,
i.e. for example in case of malfunctions due to
electromagnetic disturbance.

5.HEALTH Button

13.HOUR Adjustment

Used to set clock and timer setting

8. FILTER Button

Used to set up/down function of filter.

NOTE: 

1.Single cooling air conditioner does not have the displays and functions related to heating.

            2.Some functions of this controller maybe not available according to the corresponding PCB's functions,such
                as: In function of code A                                                               which are optional for different unit.
             3.HIGH/SO button:This button is active in Cooling/Heating mode, the fan speed is in AUTO mode after pressing
               it and " high functon/soft function  " will be automatically cancelled after 15 minutes running.

             

4.

HEAT button:

This button can only be used for units with electric heater function.

9.CODE Button

Used to select Code A or B, 

Series

 wired remote controller

units use Code A,

Series

 remote controller units use code B.

14.HIGH/SO Button

Used to select HIGH or SOFT operation.

11.LIGHT Button

Used to light the control panel (only for cabinet unit)

12.LOCK Button

Used to lock operation button and LCD display contents: by
pressing this button, other buttons comes out of function and
lock state display appears; if you press it again, lock state
will be no more active and lock state display will disappear.

The function of code B

AUTO

FAN

HEAT

COOL

DRY

FRESH

HIGH/SO

TIMER

SET

FILTER

B

A

M

D

HEALTH

RESET

LOCK

SLEEP

FAN

TEMP

ON

OFF

SWING

MODE

CLOCK

CODE

LIGHT

OFF

A
U
T
O

25

26

21

23

17

15

18

19

22

24

27

20

14

16

36

1

2

3

4

6

7

9

10

5

8

34

33

28

32

31

30

35

29

The function of code A

Used to select TIMER mode:TIMER
ON,TIMER OFF.

The function of code B

8

5

2

16

28

30 33

29

14

11

17 21 24

HEAT

13

37

12

11

HEAT

COOL

DRY

8

At night, before going to bed you can press
down the SLEEP button on the controller
and the air-conditioner will run by the
comfortable sleeping mode to make you sleep
more comfortable.

In cooling, dehumidifying mode

In heating mode

Comfortable Sleep

Note:

 In AUTO mode, unit will run in SLEEP function according to the operation mode.

          After setting SLEEP function, it is forbidden to calibrate clock.
          If the set sleep-time does not reach 8 hours, the unit will stop operation automatically after set time
          is complete.
         Set "TIMER-OFF" function first, then set SLEEP, and the sleep-set is performance; set TIMER-ON
         function first, the sleep function can only be set before TIMER-ON; if set theSLEEP function first,
         the TIMER function can not be set.

Note: Before using this function of code A, must
adjust the clock, or the sleep function will be disordered.

After setting sleep function, not allowed to adjust the clock. Can't use the remote controller operate the
AC. If so, please cancel the sleep function first.
After setting sleep function, can't set the timing function.

One hour after start up, the temp. decrease 2    lower than the setting one. After another hour decrease by
more 2   .
The temperature will automatically rise by 1    after another 3hrs' operation, and then automatically close
after 3hrs' continuous operation. The actral temperature is lower than the setting one which is to prevent
from being too hot to your sleep.

One hour after sleeping operation start, the temp. is 1    higher than the setting one. After another hour the
temp. rises 1    and then run continuously for another 6hrs' and then close. The actual temp. is higher than
the setting one which is to prevent from being too cool to your sleep.

FRESH

HIGH/SO

TIMER

SET

FILTER

A

HEALTH

RESET

LOCK

SLEEP

FAN

TEMP

ON

OFF

SWING

MODE

CLOCK

CODE

LIGHT

OFF

A
U
T
O

Operation

SETTING T

SLEEP RUN BEGINS

SLEEP RUN STOPS

1 hr

1 hr

3 hrs

about 3 hrs

decrease 2

decreases 2

increase1

SHUT DOWN

Heat  mode

about 6 hrs

1 hr

1 hr

increase 1

increase 1

SLEEP RUN STOPS

SLEEP RUN BEGINS

SETTING T

SHUT DOWN

Cooling  mode

The function of code A:Sleep function

*

MODE

FAN

HEALTH

TEMP

CLOCK

SET

TIMER

SLEEP

RESET

ON/OFF

AM

SET

OFF

AM

SWING

FILTER RESET

HEAT

HEAT

Содержание YR-E06

Страница 1: ...rmed Hint 1 Power supply switch and signal wire should be prepaired by the user 2 Don t touch PCB with hand Be careful not to hold down the wiring 1 Remove upper cover of wire controller Remove upper part of wire controller by press Lower cover of wire controller Upper cover of wire controller 2 Install the wired remote controller Please drill two holes on the wall according to the back cover scre...

Страница 2: ...l window of the remote control receiver 2 Series remote controller units please press the botton CODE to choose the program of code B 3 Series remote control units have not power failure compensation fig 2 FRESH HIGH SO TIMER SET FILTER B A M D HEALTH FRESH HIGH SO TIMER SET FILTER B A M D HEALTH Parts and Functions HEAT HEAT HEAT HEAT SET ROOM MODE FAN TEMP CLOCK SET TIMER SLEEP RESET FILTER RESE...

Страница 3: ... the Switch On Off button after the power comes again If the controller no sleep key use the swing key instead the sleeping on setting the auto restart function After the Auto restart is set if power failure suddenly occurs while the air conditioner is working it will resume the previous working state when the power is supplied again Used to adjust the time of timer and clock When the wire control...

Страница 4: ... TIMER SET FILTER B A M D HEALTH RESET LOCK SLEEP FAN TEMP ON OFF SWING MODE CLOCK CODE LIGHT OFF A U T O 25 26 21 23 17 15 18 19 22 24 27 20 14 16 36 1 2 3 4 6 7 9 10 5 8 34 33 28 32 31 30 35 29 The function of code A Used to select TIMER mode TIMER ON TIMER OFF The function of code B 8 5 2 16 28 30 33 29 14 11 17 21 24 HEAT 13 37 12 11 HEAT COOL DRY 8 At night before going to bed you can press d...

Страница 5: ...it stops at X hour X min According to the Time setting sequence of TIMER ON or TIMER OFF either Start Stop or Stop Start can be achieved 1 After unit start select your desired operation mode 2 Press TIMER button to change TIMER mode ON OFF Operation The function of code A TIMER ON OFF FRESH HIGH SO TIMER SET FILTER A HEALTH 1 HEAT MODE FAN HEALTH TEMP CLOCK SET TIMER SLEEP RESET FILTER RESET ON OF...

Страница 6: ...H SO TIMER SET FILTER A HEALTH 1 5 4 Operation The function of code B AUTO COOL DRY FAN HEAT The function of code A COOL DRY HEAT LOW MID HIGH AUTO The function of code A The function of code B LOW MID HIGH AUTO FILTERRESET HEAT HEAT 6 Hints Set Clock correctly before starting Timer operation You can let unit start or stop automatically at following time Before you wake up in the morning or get ba...

Отзывы: