Installation Instructions: Introduction and Overview
Ducted Product Information
The Ducted unit will install above the ceiling or in a
soffit area. It is mounted using threaded rods that fit into
brackets that are located at all four top corners of the
cabinet.
Each unit has a built-in condensate pump and a float
switch to avoid an overflow situation and to maintain
reliable operation. An insulated condensate fitting is
included in the accessory pouch. This fitting connects the
condensate drain outlet of the unit to the field-supplied
drain piping.
When making refrigerant line connections, always use
the flare nuts provided with this equipment. Refrigerant
line connections should be wrapped with insulating tape
at the unit to prevent sweating.
Model
A in (mm)
B in (mm)
C in (mm)
D in (mm)
E in (mm)
F in (mm)
USYM09U
30 (762)
47.7 (1212)
50 (1272)
24.4 (620)
30.1 (765)
32.5 (825)
USYM12U
USYM18U
45.7 (1162)
63.5 (1612)
65.8 (1672)
USYM24U
USYM30U
61.5 (1562)
79.2 (2012)
81.57 (2072)
USYM36U
USYM42U
USYM48U
Indoor
U
SYM09UCDSA
USYM12UCDSA
USYM18UCDSA
USYM24UCDDA
Rated Cooling Capacity Btu/hr
9,000
12,000
18,000
24,000
Rated Heating Capacity Btu/hr
10,000
13,000
19,000
26,000
Voltage, Cycle, Phase V/Hz/-
208-230/60/1
Airflow (Turbo/High/Med/Low/Quiet) CFM
424/353/294/235/176 494/424/353/294/235 735/635/541/470/400 927/844/667/564/482
Max. External Static Pressure in. W.G. (Pa)
0.6 (150)
Indoor
USYM30UCDDA
USYM36UCDDA
USYM42UCDDA
USYM48UCDDA
Rated Cooling Capacity Btu/hr
30,000
34,000
42,000
46,000
Rated Heating Capacity Btu/hr
32,000
36,000
45,000
48,000
Voltage, Cycle, Phase V/Hz/-
208-230/60/1
Airflow (Turbo/High/Med/Low/Quiet) CFM
1236/1130/953/812/688
1412/1353/1141/965/847
Max. External Static Pressure in. W.G. (Pa)
0.6 (150)