Haier Sea Elephant PJF2-150W Скачать руководство пользователя страница 6

REG MODE

SET

ON/OFF

SOL H  PRE  INT    WT   HC

  

T-DISP

REG MODE

SET

ON/OFF

T-DISP

Ì «

Ñ ô

Ä Ü

SOL H PRE

INT WT

  

HC

REG

MODE

SET

ON/OFF

T-DISP

SOL H PRE

INT WT

  

HC

SOL H PRE

INT WT

  

HC

T-DISP

SET

ON/OFF

REG MODE

3

12

Note: the above parameter errors ( except power value) of the lighting area are 

3%, 

volume errors are 

 3%, and the allowed error scope of other sizes is

10%.

¼ ¯

È È

Æ ÷

° ü

× °

Ï ä

Technical parameter Packing list

Technical parameter

Packing list

Use method

Model 

Volume

Water-proof 
     Grade

Drip-proof

Rated internal 
     Pressure

Size

Model

Rated  voltage

 

Frequency

Rated  Power    

Input

Grass Collector area

BRF2-150W

PJF2-150W

230V~

230V~

50Hz

50Hz

2200W

2200W

0.7MPa

0.7MPa

492

530

1380(mm)

3.0m

2

4.0m

2

Drip-proof

Name of components

Packing method

Packing container
o f   w a t e r   t a n k

BRF2-150W

PJF2-150W

Users manual 

Model

Tee joint*

Opposite wires S1/2F-3/4M

Packing  of solar stage

1

3/4

 fiber spacer

Collector equipment

Single-direction valve*

1

4

4

1

1

2

2

1

1

1

1

Packing of collector

Note: accessories of BRF2-150W and PJF2-150W products are suitable only for oblique 
installment. For flat installment, prop stand of different angles should be made according 
to requirements, which is not included in the packing accessories.The part of after which 
have * will be carried by server when installation.

Water-storing tank

1

Temperature and pressure valve*

numbers.when set the  parameter up to the 
highest,press the setting key again,the 
number will increase  progressivelyfrom 
the minimal number.to continually press   

  

 more than one second, the adjusted 

parameter will increase progressively 3 
numbers every second setting of each 
parameter can be done by pressing the 
setting key or by not pressing the setting 
key about 6 seconds. Then the system will 
automatically confirm and automatically 
enter the next parameter setting, until the 
system finally withdraws from the set 
conditions and returns to the conditions of 
the previous clock. The set order of 
parameter in specific modes is as follows: 

Solar energy heating mode:

Indicating clock condition---to check the 
hour of clock---to check the minute of 
clock---to set temperature difference of 
water pump running--- indicating clock 
c o n d i t i o n .   F o r   e x a m p l e :  t e m p e r a t u r e  
difference value setting of water pump 
running: to press the setting key to enter 
t h e   s e t t i n g   c o n d i t i o n  o f   t e m p e r a t u r e  
difference of water pump running. The 
indication board indicates the present set 
value (the first place on the left of the clock 
number tube indicates 

L

, and the 

following two places indicate the tacitly 
approved set value, which is 15

). To 

press the setting key to select between 15 

 and 10

. For the indication interface, 

see Fig.11.

Simultaneous heating mode:

I n d i c a t i o n   c l o c k  c o n d i t i o n - - -   t h e 
temperature of heating---indication clock 
condition.

Preset heating mode: 

Indicating clock condition---to set hour of 

`

492

530

1380(mm)

150L

150L

BRF2-150W

PJF2-150W

Affusing liquid valve*

Small expanding bolt

Large expanding bolt

Solar stage pothook

Expanging tank fixity

Expanding tank 

Solar stage

Fig.9 solar heating interface

Fig.11 temperature difference 
 setting interface for water pump

Fig.10  turning off interface

Fig.12   Temperature setting interface for 
                    The first time preset heating

1

2

Содержание Sea Elephant PJF2-150W

Страница 1: ...ertificate of Quality Sea Elephant Rev 01 specific number 0040570098 Solar waterheater Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF2 150W BRF2 150W ...

Страница 2: ...ironment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of m a t e r i a l r e s o u r c e s To r e t u r n y o u r u s e d device please use the return and collection systems or contact the retailer where the product was purchased they can take this product for environmental safe recycling Note 16 ...

Страница 3: ...ction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair section Contact repair section Contact repair section Contact re...

Страница 4: ...ppliance is damaged it is the personnel of after service who change that for specially designed lines provided by the manufacturer 10 In cases when the temperature of water storing tank exceeds 85 and the electrical enclosure indicates E2 First you should cut off power supply then to release a little of hot water and supply some cold water when the temperature of water is decrease and then to conn...

Страница 5: ...e pipe of circulating pipe screw down the the cap of the affusing liquid valve open the two small halt valves the antifreeze will flow from the small halt valve put it on something when the antifreeze stop flowing close the big halt valve in the middle of affusing liquid valve connect inflator to liquid hole the method is same with the method of affusing antifreeze sure the gas direction and the s...

Страница 6: ...an one second the adjusted parameter will increase progressively 3 numbers every second setting of each parameter can be done by pressing the setting key or by not pressing the setting key about 6 seconds Then the system will automatically confirm and automatically enter the next parameter setting until the system finally withdraws from the set conditions and returns to the conditions of the previ...

Страница 7: ...ethod sensor malfunction alarm of water storing tank E4 etc When these problems happen the system will display malfunction code E1 E4 The above malfunction protection is non restorable and therefore the system can only normally run after malfunction is eliminated and the electricity is re connected 3 Interface indication and instruction for operation After the solar water heater center is installe...

Страница 8: ...this function automatically works out the time needed to the set temperature according to the default heating power 2 2KW and then ensures the time when water heater begins to heat This mode can realize both one time preset and twice preset You can choose either heating method based on your practical life necessity If you need one time preset heating you just need to press the setting mode to set ...

Страница 9: ...ng mode When the red light is glistening it tells that the system in electrical heating and when it reaches the mounted temperature the green point will be on constantly L5 Yellow when the character is on it tells the temperature of water storing tank L6 Red when the character is on it tells the temperature of water exiting temperature of collector equipment Í È ý È È Æ µ Ä Use methed For the firs...

Страница 10: ...the sign of N on the relay is corresponding to the N of power supply line then the sensor of tank should be connecte to the power supply board and insert it tightly Finally press the power supply line tightly install again the solar stage cover and to screw tightly the self tapping screw To fill up the tank To open water exiting valve of hot water and to fill water into the tank through cold water...