Temperature Display of 
the tank or collecter

Clock display and set

Fig.8 Indication board

7

Installation

8

Introduction for the controller

Installation

Pressure handle 

Pressure relief vent

Fig.7 S

 

ketch map of tempreture

 

  

 

 And pressure valve

 

On Outdoors circulating liquid-returning of collector,and the direction of 
Single direction valve2 and circulating liquid-returning pipe must be 
same,please see Fig1-Fig.2

Connection and Use of temperature and pressure valve

When the temperature rise, a little water will drip from pressure relief vent on 
the temperature and pressure valve due to normal expansion. The vent shall 
be installed downwards and always keep open to the air. Avoid being 
blocked.   
Note: If your water heater is not installed in a bathroom with sewage drain, it 
is suggested you connect a drain hose (separately sold) to the temperature 
and pressure valve. Connect one end of the hose to the temperature and 
pressure valve vent and the other end to the sewage drain. The hose can be 
cut short or extended as necessary. The hose shall be installed as inclined 
downward.
Note: the mixing valve is separately sold,you can get it from the local 
service,and contact the appointed professional serving personnel for 

Connection of affusing liquid valve and 
expanding tank

Fix the affusing liquid valve on the top water-
outlet of solar stage(the pipe of connection with 
pump), affusing liquid valve is no direction 
demand,but the room arond affusing liquid 
v a l v e   s h o u l d  b e   b i g , a s  t o   a f f u s e  l i q u i d  
conveniencly. Fix a tee joint on the outlet of 
the top hole of the tee joint should be connected to circulating water-outlet 
pipe, ensure the place, to drill 2 holes 70mm deep, 

9mm on the wall, use 

two small bolt to fix the expanding tank on the wall with expanding tank 
strap,please see Fig.1-Fig.2.
Note: affusing liquid valve and expanding tank should be connected to the 
Corresponding pipe of  circulating water-outlet of tank.

Connection of controlling equipment

Controlling equipment of the water heater is composed of power supply 
board and indication board. Both are inside the solar stage.Open the shell of 
solar stage , according to the electrical connection principle figure : connect 
the L

N of power supply line which connects heating element to the L

N of 

relay fan-out( the sign of N on the relay is corresponding to the N of power 
supply line) , then the sensor of tank should be connecte to the power supply 
board, and insert it tightly, Finally, press the power supply line tightly, install 
again the solar stage cover,and to screw tightly the self-tapping screw.

 

To fill up the tank

To open water-exiting valve of hot water and to fill water into the tank,through 
cold water meatus of tap water. To close water exiting valve of hot water until 
the air is exhausted and water flows out continually. Meanwhile, to observe 
whether the system leaks and to keep the cold water entrance open in the 
process of use. 

Affuse antifreeze

Screw down the cap of affusing liquid valve,close the big halt valve in the 
middle of affusing liquid valve( note:when the handle of the valve and axes of 
the valve are vertical, the valve is closed),open the other small halt valve,put 
the liquid-exiting of the equipment to one affusing liquid hole,make sure the 

flow direction of 

antifreeze

 and Single direction valve 2 are the same, and 

the other affusing liquid hole connect the liquid-returning of the equipment, 

start the liquid equipment, at the same time, observe the 

antifreeze

 untill 

returning 

antifreeze

 is well-proportioned, and no air bladder.firstly close the 

halt valve which connect the liquid-returning equipment, then close the the 
halt valve which connect the liquid-exiting equipment,then open the big halt 
valve in the middle of affusing liquid valve, remove the equipment.

Note: after affusing the 

antifreeze

, put the 3/4

fiber spacer to the cap of the 

affusing liquid valve, and screw tightly the the cap of the affusing liquid valve, 

to avoid the 

antifreeze

 flowing from the tank.

L1--L4 indicator lights respectively represent the 
four modes of the system working, among  which  
L2--L4 lights are all double color , L5--L6 lights  
respectively represent  the t

For details as  follows:
L1(green)---when the green light is on, it indicates 
that the system is woking on the solar energy 
heating mode.
L2(Double colors)---when the green light is on, it 
indicates that the system is working on the  instant 
heating mode. When the red light is glittering, it 

emperatures of the 

upper tank and outlet of the collector.

Introduction for the controller 

Indicates heating up.
L3(Double colors)---when the green light is on, it indicates  that the system is 
working on the preset heating mode. When the red light is glittering, it 
indicates that the system is heating up ,and will be green as  it reaches the 
preseted temperature, the green point will be on constantly.

Installation

Содержание Sea Elephant PJF2-150W

Страница 1: ...ertificate of Quality Sea Elephant Rev 01 specific number 0040570098 Solar waterheater Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF2 150W BRF2 150W ...

Страница 2: ...ironment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of m a t e r i a l r e s o u r c e s To r e t u r n y o u r u s e d device please use the return and collection systems or contact the retailer where the product was purchased they can take this product for environmental safe recycling Note 16 ...

Страница 3: ...ction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair section Contact repair section Contact repair section Contact re...

Страница 4: ...ppliance is damaged it is the personnel of after service who change that for specially designed lines provided by the manufacturer 10 In cases when the temperature of water storing tank exceeds 85 and the electrical enclosure indicates E2 First you should cut off power supply then to release a little of hot water and supply some cold water when the temperature of water is decrease and then to conn...

Страница 5: ...e pipe of circulating pipe screw down the the cap of the affusing liquid valve open the two small halt valves the antifreeze will flow from the small halt valve put it on something when the antifreeze stop flowing close the big halt valve in the middle of affusing liquid valve connect inflator to liquid hole the method is same with the method of affusing antifreeze sure the gas direction and the s...

Страница 6: ...an one second the adjusted parameter will increase progressively 3 numbers every second setting of each parameter can be done by pressing the setting key or by not pressing the setting key about 6 seconds Then the system will automatically confirm and automatically enter the next parameter setting until the system finally withdraws from the set conditions and returns to the conditions of the previ...

Страница 7: ...ethod sensor malfunction alarm of water storing tank E4 etc When these problems happen the system will display malfunction code E1 E4 The above malfunction protection is non restorable and therefore the system can only normally run after malfunction is eliminated and the electricity is re connected 3 Interface indication and instruction for operation After the solar water heater center is installe...

Страница 8: ...this function automatically works out the time needed to the set temperature according to the default heating power 2 2KW and then ensures the time when water heater begins to heat This mode can realize both one time preset and twice preset You can choose either heating method based on your practical life necessity If you need one time preset heating you just need to press the setting mode to set ...

Страница 9: ...ng mode When the red light is glistening it tells that the system in electrical heating and when it reaches the mounted temperature the green point will be on constantly L5 Yellow when the character is on it tells the temperature of water storing tank L6 Red when the character is on it tells the temperature of water exiting temperature of collector equipment Í È ý È È Æ µ Ä Use methed For the firs...

Страница 10: ...the sign of N on the relay is corresponding to the N of power supply line then the sensor of tank should be connecte to the power supply board and insert it tightly Finally press the power supply line tightly install again the solar stage cover and to screw tightly the self tapping screw To fill up the tank To open water exiting valve of hot water and to fill water into the tank through cold water...

Отзывы: