Haier Sea Elephant PJF2-150W Скачать руководство пользователя страница 5

13

Use method

The first preset heating time .---to set minute of the first preset heating time--
-to set temperature of preset heating .--- to set hour of the second preset 
heating time --- to set minute of the second preset heating time---to set 
temperature of the second preset heating ---indicating clock condition. For 
example: to  Set the temperature of the first preset heating, and for the 
indication interface,see Fig.12.

Intellectual heating mode:

Indicating clock condition--the temperature of heating --- indicating clock 
condition. 
Note: Only when the present working mode is selected, can the 
corresponding set content be carried out.

1.To avoid that water spurts out to the solar stage  and the top cover of water-

storing tank directly.

2.To check the functioning of the system regularly and to check whether the 

computer board works normally.

3. In order to ensure excellent running of solar water heater, you are suggested 

to keep the controller electrified constantly and keep it working under the 
solar energy heating mode.

4.In normal use, the tap water entrance valve of water-storing tank should be 

kept constantly open. You only need to open the mixed valve to adjust water 
temperature when taking a bath and then you can use freely.

5.In summer when water heater is not used for long, the system should not be 

closed so as to avoid that the collector is too hot. When empty the system, you 
should empty the tank and the collector. The emptying method of the tank is to 
close the valve where tap water pipe leads to the hot water system, to open 
the decompression handle of tempteture and pressure valve and remove the 
single direction valve1 and to empty the tank.

   the emptying method of the pipe of circulating pipe:screw down the the cap of 

the affusing liquid valve, open the two small halt valves, the antifreeze will 
flow from the small halt valve,put it on something,when the antifreeze stop 
flowing,close the big halt valve in the middle of affusing liquid valve,connect 
inflator to liquid hole,the method is same with the method of affusing 
antifreeze, sure the gas direction and the single direction valve2 is same untill 
the antifreeze is cleaned up.

6.Please try to connect the probe of sensor to the bottom of the installed hole in 

installment or repair. Please avoid that the sensor receives wrong signals.

7.Affusing liquid valve is the key part of the system,aviod to adjust or remove 

the 3 handles and 2 screw caps, if temperature of the tank is low, please 

Notes for  usage

Notes for usage

Flat collector

Hot water outlet 

 

Cold water inlet
 

Tee joint

Metal pipe: ( copper or corrugation pipe)

Water-storing tank

Outdoors
Indoors

Single direction valve1

Temperature and 
  pressure valve

Vacuum tube Collector

Single direction valve2

Solar stage

Affusing liquid valve

Expanding tank

circulating liquid-exiting

 

circulating liquid-returning

circulating liquid-returning

Metal pipe: ( copper or corrugation pipe)

Single direction valve2

circulating 
liquid-exiting

 

Outdoors
Indoors

Tee joint

Affusing liquid valve

Expanding tank

Solar stage

Single direction valve1

Cold water inlet
 

Temperature and 
  pressure valve

Hot water outlet 

 

Water-storing tank

2

System structure

Fig.1  BRF2-150W  structure sketch map

Fig.2  PJF2-150W  structure sketch map

Í ¼ È ý

    ¼ ¯

È È Æ ÷

µ Ä ° ²

× °

Decorating object

Crculating water-inleting

Tempreture and 
pressure valve

Inside line

Tank sensor

Circulating water-outleting

Top cover

H

o

t w

a

te

r o

u

tle

t

Osculum

Top cover

Tank sensor

Inside line

Fig.3  Circulating of tank 

 

structure platform

Fig.4  Circulating of tank 

structure 

sketch map

Electric controller 

 

Содержание Sea Elephant PJF2-150W

Страница 1: ...ertificate of Quality Sea Elephant Rev 01 specific number 0040570098 Solar waterheater Please read this manual carefully before use Please keep this manual for future reference User s Manual PJF2 150W BRF2 150W ...

Страница 2: ...ironment or human health from uncontrolled waste disposal recycle it responsibly to promote the sustainable reuse of m a t e r i a l r e s o u r c e s To r e t u r n y o u r u s e d device please use the return and collection systems or contact the retailer where the product was purchased they can take this product for environmental safe recycling Note 16 ...

Страница 3: ...ction Is the sensor of collector damaged Is it connected well with power supply board Is the sensor of storing tank damaged Is it connected well with power supply board Whether tap water pressure is too large over 0 7MPa Check Check and clean Readjust Contact repair section Heat continually Contact repair section Check Contact repair section Contact repair section Contact repair section Contact re...

Страница 4: ...ppliance is damaged it is the personnel of after service who change that for specially designed lines provided by the manufacturer 10 In cases when the temperature of water storing tank exceeds 85 and the electrical enclosure indicates E2 First you should cut off power supply then to release a little of hot water and supply some cold water when the temperature of water is decrease and then to conn...

Страница 5: ...e pipe of circulating pipe screw down the the cap of the affusing liquid valve open the two small halt valves the antifreeze will flow from the small halt valve put it on something when the antifreeze stop flowing close the big halt valve in the middle of affusing liquid valve connect inflator to liquid hole the method is same with the method of affusing antifreeze sure the gas direction and the s...

Страница 6: ...an one second the adjusted parameter will increase progressively 3 numbers every second setting of each parameter can be done by pressing the setting key or by not pressing the setting key about 6 seconds Then the system will automatically confirm and automatically enter the next parameter setting until the system finally withdraws from the set conditions and returns to the conditions of the previ...

Страница 7: ...ethod sensor malfunction alarm of water storing tank E4 etc When these problems happen the system will display malfunction code E1 E4 The above malfunction protection is non restorable and therefore the system can only normally run after malfunction is eliminated and the electricity is re connected 3 Interface indication and instruction for operation After the solar water heater center is installe...

Страница 8: ...this function automatically works out the time needed to the set temperature according to the default heating power 2 2KW and then ensures the time when water heater begins to heat This mode can realize both one time preset and twice preset You can choose either heating method based on your practical life necessity If you need one time preset heating you just need to press the setting mode to set ...

Страница 9: ...ng mode When the red light is glistening it tells that the system in electrical heating and when it reaches the mounted temperature the green point will be on constantly L5 Yellow when the character is on it tells the temperature of water storing tank L6 Red when the character is on it tells the temperature of water exiting temperature of collector equipment Í È ý È È Æ µ Ä Use methed For the firs...

Страница 10: ...the sign of N on the relay is corresponding to the N of power supply line then the sensor of tank should be connecte to the power supply board and insert it tightly Finally press the power supply line tightly install again the solar stage cover and to screw tightly the self tapping screw To fill up the tank To open water exiting valve of hot water and to fill water into the tank through cold water...