background image

 

7

Installation instructions 

y

 

Schematic drawing of the indoor pipeline and wiring 

 

 

y

 

Precautions in pipeline installation 

1.

 

Any form of modification of the installation structure of the water heater may cause problems in use. 

2.

 

There are 5 ways for the heater pipeline to enter the house: flue, exhaust pipe, penetrating hole, special 

pipeline well for solar water heater, embedded bushing. Of which the first 3 are relatively popular. Before 

installing the pipeline, the installation personnel will discuss the entering way and installation position of the 

pipeline with you for your convenient use. During piping, the penetrating hole must have an adverse slope 

and be sealed properly to prevent rain and odor from coming into the house. 

3.

 

The overflow pipe must be fastened firmly and its indoor opening must be kept downward. The overflow 

water can be discharged directly into the sewer. The distance between the opening of the overflow pipe and 

the sewer plane should not be more than 15cm. Never hang the overflow pipe arbitrarily as splash of large 

amount of overflow water will damage articles in your house. 

4.

 

Never install valve in the overflow pipeline to ensure rapid, accurate transfer of Full-of-Water signal. 

5.

 

Check valves should be installed on the trunks of water supply and drain pipes that are connected with the tap 

water pipe to prevent back flowing of water in the tank. 

6.

 

When several water heaters are combined, the installation plan should be validated by a professional service 

person of Haier. 

Solar water heater

 

Tap water 

Hot water 

O

v

erflow

 p

ipe

Содержание S110ENF

Страница 1: ...1 Haier Solar Water Heater User s Manual S75ENF S85ENF S110ENF S125ENF S150ENF S75ENL S85ENL S110ENL S125ENL S150ENL z Please read this manual before usage z Retain it for future reference ...

Страница 2: ...the horizontal water heater 4 Assembly the bracket 5 Securing the bracket 5 Installing the water tank 5 Installing the vacuum tubes 6 Schematic drawing of the indoor pipeline and wiring 7 Precautions in pipeline installation 7 Connection method of water supply pipeline in the houses where a solar water heat coexists with another type of water heater 8 Operation instructions Operation method 8 FAQ ...

Страница 3: ...steel panel by shaping and plastic spraying It has the advantages of stable structure beautiful appearance anti corrosion and so on y Parameters Model Volume of useable water L Size of the vacuum tubes Bracket form Quantity of the vacuum tubes Aperture area Total water volume L S75ENF 75 φ47X1500 mm Flat roof 45º 14 1 33 96 S85ENF 85 φ47X1500 mm Flat roof 45º 16 1 52 108 S110ENF 110 φ58X1800 mm Fl...

Страница 4: ...due to the height difference between the water tank and the water usage point The output pressure is proportional to the height difference If the height difference is too low it will not function normally In this case an effluent booster should be fitted 6 When sunshine is not sufficient to ensure effect you should avoid using hot water several times in one day 7 The energy source of this water he...

Страница 5: ...e water heater may cause serious burns Be sure to take a shower or wash after mixing the hot water with cold water 3 To ensure normal use never refit it or block the ventilation pipe and overflow pipe Otherwise the water tank will shrink due to negative pressure y Selection of installation location 1 In areas where lightning strikes frequently occur the water heater shall be installed within the l...

Страница 6: ...ions in mm Model A H D B S75ENF 1166 1457 1000 1351 S85ENF 1306 1457 1140 1351 S110ENF 1296 1710 1140 1590 S125ENF 1456 1710 1300 1590 S150ENF 1696 1710 1540 1418 S75ENL 1166 1457 1000 1351 S85ENL 1306 1457 1140 1351 S110ENL 1296 1710 1140 1590 S125ENL 1456 1710 1300 1590 S150ENL 1696 1710 1540 1418 Note error of above dimensions ...

Страница 7: ...ns frequently fix the water tank and bracket firmly on the roof with wire rope 3 The water heater must be installed stably and firmly Otherwise serious damage or injury may occur in bad weather y Installing the water tank 1 Take the water tank from the packing case and remove the nuts and shims attached to the bolts on both sides of the tank 2 Insert the bolts on the bottom of the tank into the lo...

Страница 8: ... vacuum tube into the seal ring should be about 1cm Push the wind shroud onto the water tank to plug the joint Fig D 6 When installing the vacuum tubes one tube should be installed on each side of the water tank first so that the water tank and bracket can be positioned as a whole Notes 1 Check if the seal rings in the tank holes are all ready if the sealing planes are clean free of foreign bodies...

Страница 9: ...to prevent rain and odor from coming into the house 3 The overflow pipe must be fastened firmly and its indoor opening must be kept downward The overflow water can be discharged directly into the sewer The distance between the opening of the overflow pipe and the sewer plane should not be more than 15cm Never hang the overflow pipe arbitrarily as splash of large amount of overflow water will damag...

Страница 10: ...alve K1 3 To use hot water open valve K2 Hot water will come out from the shower nozzle If it is too hot open valve K3 to adjust the water temperature 4 Close valves K2 and K3 after use To the tank of the solar water heater Another type of water heater When a solar water heat coexists with another type of water heater check valves must be installed on both cold and hot water pipes to avoid damage ...

Страница 11: ...ine or joints Repair or replace the pipeline or joints The water supply valve is not closed tightly or it is damaged Close the valve tightly or replace the damaged valve There is shading object in the front of the vacuum tubes and they cannot collect heat effectively Remove the shading object or relocate the water heater Too low temperature of the hot water Too much dust on the vacuum tubes Clean ...

Страница 12: ...10 Rev 1 Specific number 0040502052 ...

Отзывы: