background image

 

9

Operation instructions 

y

 

FAQ 

Troubles Possible 

reasons 

Solutions 

The water tank becomes empty 

Add water according to the time 

required in the instruction manual 

No outlet water 

Disconnection or blockage of the 

pipeline or joints 

Repair the pipeline or remove the 

blockage 

Broken vacuum tube(s) 

Replace the broken tube(s) 

Water supply is stopped or water 

pressure is too low 

Wait until the water supply 

becomes normal 

No water comes from the overflow 

pipe 

Disconnection or break of the 

pipeline or joints 

Repair or replace the pipeline or 

joints 

The water supply valve is not 

closed tightly or it is damaged 

Close the valve tightly or replace 

the damaged valve 

There is shading object in the front 

of the vacuum tubes and they 

cannot collect heat effectively 

Remove the shading object or 

relocate the water heater 

Too low temperature of the hot 

water 

Too much dust on the vacuum 

tubes 

Clean the surface of the vacuum 

tubes 

 

 

y

 

Packing list 

 

Quantity 

Main components 

75L  85L  110L 125L 150L 

Water tank (pc) 

Water tank 

User’s Manual (copy) 

Left tank support (pc) 

Tank 

support 

case 

Right tank support (pc) 

Vacuum 

tube 

(pc) 

14 16 14 16 19 

Bracket 

(set) 

1 1 1 1 1 

 

Содержание S110ENF

Страница 1: ...1 Haier Solar Water Heater User s Manual S75ENF S85ENF S110ENF S125ENF S150ENF S75ENL S85ENL S110ENL S125ENL S150ENL z Please read this manual before usage z Retain it for future reference ...

Страница 2: ...the horizontal water heater 4 Assembly the bracket 5 Securing the bracket 5 Installing the water tank 5 Installing the vacuum tubes 6 Schematic drawing of the indoor pipeline and wiring 7 Precautions in pipeline installation 7 Connection method of water supply pipeline in the houses where a solar water heat coexists with another type of water heater 8 Operation instructions Operation method 8 FAQ ...

Страница 3: ...steel panel by shaping and plastic spraying It has the advantages of stable structure beautiful appearance anti corrosion and so on y Parameters Model Volume of useable water L Size of the vacuum tubes Bracket form Quantity of the vacuum tubes Aperture area Total water volume L S75ENF 75 φ47X1500 mm Flat roof 45º 14 1 33 96 S85ENF 85 φ47X1500 mm Flat roof 45º 16 1 52 108 S110ENF 110 φ58X1800 mm Fl...

Страница 4: ...due to the height difference between the water tank and the water usage point The output pressure is proportional to the height difference If the height difference is too low it will not function normally In this case an effluent booster should be fitted 6 When sunshine is not sufficient to ensure effect you should avoid using hot water several times in one day 7 The energy source of this water he...

Страница 5: ...e water heater may cause serious burns Be sure to take a shower or wash after mixing the hot water with cold water 3 To ensure normal use never refit it or block the ventilation pipe and overflow pipe Otherwise the water tank will shrink due to negative pressure y Selection of installation location 1 In areas where lightning strikes frequently occur the water heater shall be installed within the l...

Страница 6: ...ions in mm Model A H D B S75ENF 1166 1457 1000 1351 S85ENF 1306 1457 1140 1351 S110ENF 1296 1710 1140 1590 S125ENF 1456 1710 1300 1590 S150ENF 1696 1710 1540 1418 S75ENL 1166 1457 1000 1351 S85ENL 1306 1457 1140 1351 S110ENL 1296 1710 1140 1590 S125ENL 1456 1710 1300 1590 S150ENL 1696 1710 1540 1418 Note error of above dimensions ...

Страница 7: ...ns frequently fix the water tank and bracket firmly on the roof with wire rope 3 The water heater must be installed stably and firmly Otherwise serious damage or injury may occur in bad weather y Installing the water tank 1 Take the water tank from the packing case and remove the nuts and shims attached to the bolts on both sides of the tank 2 Insert the bolts on the bottom of the tank into the lo...

Страница 8: ... vacuum tube into the seal ring should be about 1cm Push the wind shroud onto the water tank to plug the joint Fig D 6 When installing the vacuum tubes one tube should be installed on each side of the water tank first so that the water tank and bracket can be positioned as a whole Notes 1 Check if the seal rings in the tank holes are all ready if the sealing planes are clean free of foreign bodies...

Страница 9: ...to prevent rain and odor from coming into the house 3 The overflow pipe must be fastened firmly and its indoor opening must be kept downward The overflow water can be discharged directly into the sewer The distance between the opening of the overflow pipe and the sewer plane should not be more than 15cm Never hang the overflow pipe arbitrarily as splash of large amount of overflow water will damag...

Страница 10: ...alve K1 3 To use hot water open valve K2 Hot water will come out from the shower nozzle If it is too hot open valve K3 to adjust the water temperature 4 Close valves K2 and K3 after use To the tank of the solar water heater Another type of water heater When a solar water heat coexists with another type of water heater check valves must be installed on both cold and hot water pipes to avoid damage ...

Страница 11: ...ine or joints Repair or replace the pipeline or joints The water supply valve is not closed tightly or it is damaged Close the valve tightly or replace the damaged valve There is shading object in the front of the vacuum tubes and they cannot collect heat effectively Remove the shading object or relocate the water heater Too low temperature of the hot water Too much dust on the vacuum tubes Clean ...

Страница 12: ...10 Rev 1 Specific number 0040502052 ...

Отзывы: