background image

Haier solar water heater

 

    

3

Installation introduction

Installation Consideration

•  It is prohibited to install the collector upside down.
•  The collector shall be installed toward the south as much as possible.
•  The distance of the single pipeline between the storage water tank and the collector shall 

be less than 10m.

•  The indoor and outdoor pipeline of the system shall use the metal tube.
•  The solar station, feed valve and expansion tank shall be installed in the circular outlet 

pipeline of the storage water tank. 

•  It is  suggested  for  the  thermal  insulation  of  the  pipeline  to  use  the dedicated thermal 

insulation material of our company. 

•  The sensor for the solar collector shall be installed at the outlet of the solar collector.
•  The inlet/outlet pipeline of the panel solar collector shall be connected in the diagonal  

position,  the antifreeze flows into underneath  the inlet/outlet pipeline and above of the 

inlet/outlet pipeline.

Installation of Solar Collector

•  Use the steel wire rope with the diameter of 6mm to install the solar collector.
•  If there is no proper fixing point in the roof, it can use the large expansion bolt for the 

fixation at the thick wall.

•  There shall be some space between the solar collector and the roof,  to  prevent  the  

backflow  of  the  water  in  the  roof  from causing the leakage of the roof.

•  Custom made support of our company shall be adopted for the installation of solar 

collector on the flat roof.

Panel Solar Collector

Expansion Bolt

Steel Wire Rope

(Installation  of  the  solar 

collector on the pent roof)

 

Alert

•  If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or 

similarly qualified persons in order to avoid a hazard.

•  Make sure to test the water temperature before use.
•  The temperature pressure valve and discharge pipe are to be operated regularly to remove 

lime deposits and to verify that it is not blocked.

Содержание PJF2-200

Страница 1: ...e use 2 Installation introduction 3 Installation Consideration 3 Installation of Solar Collector 3 Installation of StorageWaterTank 5 Installation of the solar station 5 Installation of expansion water tank and priming valve 6 Priming antifreeze 6 Circuit connection 7 Pipeline Connection 8 Directions for use 9 Directions for buttons and indication lamps 9 Operation methods 11 Cleaning and Servicin...

Страница 2: ...ional personnel The water may drip from the discharge pipe of the temperature pressure valve and that this pipe must be left open to the atmosphere Children should be supervised to ensure that they do not play with the appliance This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they h...

Страница 3: ...eeze flows into underneath the inlet outlet pipeline and above of the inlet outlet pipeline Installation of Solar Collector Use the steel wire rope with the diameter of 6mm to install the solar collector If there is no proper fixing point in the roof it can use the large expansion bolt for the fixation at the thick wall There shall be some space between the solar collector and the roof to prevent ...

Страница 4: ...sion tank Safety valve Priming valve Priming outlet Solar station Priming inlet Circulation liquid inlet of water storage tank Circulation liquid outlet of water storage tank Drain outlet outdoor indoor Check valve Circulation output tube Solar collector temperature sensor wire Liquid outlet of solar collector Blind tube for measuring temperature Water storage tank HC SOL H WT PRE INT T DISP ON OF...

Страница 5: ... valve which is a normal situation If your water heater is not installed near to the sewer It is suggested to install the drain pipe of the temperature pressure valve to prevent the spatter indoors The drain pipe must be left open to the atmosphere Connect the power cable of the storage water tank and the sensor to the correct position of the power panel for the solar station Installation introduc...

Страница 6: ...g equipment for priming Observe the returned antifreeze until uniform returned flow and no bubble is realized At first close the check valve connected to returning inlet of priming equipment then the check valve connected to outlet of priming equipment and open the bigger check valve in the middle of priming valve Disassemble the priming equipment 1 1 2 2 3 3 Installation of expansion water tank a...

Страница 7: ... end Wire interface of water pump Relay output N end Relay output N label Water storage tank sensor interface Signal wire interface of Display board Creepage detection coil interface Clamp for holding the wire Earth plate Schematic diagram of power plate interface of solar station Installation introduction Circuit connection 2 3 4 1 Notice The nominal cross sectional area of the wires shall not le...

Страница 8: ...sconnected points of lead must be avoided to be in outdoor environment to prevent corrosion and oxidation due to rain Schematic diagram of wiring position of solar collector temperature sensor unit mm cut off connection here Installation introduction 2 3 1 Measure the distance from the solar collector inlet to the expansion tank and the distance from the solar collector outlet to the storage water...

Страница 9: ... presetted heating and intelligent heating At the same time indication light of corresponding mode is lighted up 2 second pause automatically confirms the mode and then enter the mode Press the button and press the button to adjust the corresponding parameters in 6 seconds Press the button for more than one second the value will increase by 3 jump per second After the setting press the button for ...

Страница 10: ... light turns green Intelligent heating indication light green red While the green light is on it is indicated that water heater is in intelligent heating working mode While the red light is on it is indicated that water heater starts electric heating working mode when the temperature is heated to the set value indication light turns green Temperature indication light of water storage tank yellow W...

Страница 11: ...ference is lower than 3 C then circulation pump stops working It is suggested that the set temperature difference of circulation pump shall be 15 C in summer and 8 C in winter Directions Q Q After setting the dated time and temperature the system will heat water to the dated temperature before dated time When it is the dated time the system will maintain the temperature for 30 minutes while the cu...

Страница 12: ... heating mode the system will divide the whole day into 8 parts Record the period part with water usage times exceeding 4 in 7 days and in the 8th day finish the heating course before in the period part and maintain the temperature for 30 minutes Notice In the instant heating mode solar energy temperature difference circulation will be in normal operation Notice If water temperature continuously d...

Страница 13: ...lar collector circular pipeline respectively Drain the storage water tank Close the inlet valve of the storage water tank Remove the end cap at the drain outlet Open the handle of the temperature pressure relief valve in the storage water tank Drain the water in the storage water tank from the drain outlet Drain the solar collector circular pipeline Unscrew the feeding cap in the priming valve and...

Страница 14: ...ge water tank 200L 300L Waterproof level of storage water tank I PX1 Waterproof level of solar station I PX1 Rated internal pressure 0 70MPa Dimension of storage water tank mm 600 638 1250 600 638 1720 Dimension of solar station mm 370 292 145 Daylighting area of solar collector 3 8m2 5 7m2 Maximum water supply pressure 0 45MPa Rated voltage 220V 230V Frequency 50Hz Electric assistant heating powe...

Страница 15: ...Use the electric heating method The pipe heater is damaged Contact the after sales service department The anti freezing fluid is not enough Fail to start the equipment It is not powered on the power supply socket is not switched on or the control panel is damaged Display the failure code The line is failed and there is the leakage for the system Display the failure code The storage water tank is n...

Страница 16: ...rt name Quantity Packing box of storage water tank Storage water tank 1 Specification 1 Check Valve 2 Tee Valve 1 Temperature pressure valve 1 Large expansion bolt 4 3 4 fiber gasket 2 Stopper 2 Connector 200L 6 Connector 300L 10 Drain pipe 1 Nipple S1 2F 3 4M 3 Solar collector Solar collector 200L 2 Solar collector 300L 3 Packing box of solar station Solar station rack 1 Fixing band of expansion ...

Отзывы: