21
Electricit
y
leakage
of
temperat
ure
controlle
r
1. The service time is too long.
2. The environment is too dirty.
3. Humidity is too high.
1. Change temperature controller.
2. Use brush to remove dust.
3. Make the te mperature dry and
control the environment humidity.
Tempera
ture
controlle
r out of
order
1. There is l eakage of tem perature
sensing medium.
2. Damage of cam of cont acting
point spring, etc.
Change temperature controller.
The
probe o f
temperat
ure
sensing
tube
doesn’t
contact
evaporat
or well
It has not been mounted to position or
changed during transportation.
Mount it again.