20
Compressor
buzzes and
cannot be
started,
thermal
protection unit
jump
repeatedly.
1. Voltage is too low.
2. Starting relay out of order.
3. The st arting coi l o f st arting
motor is broken.
4. Compressor does not run.
1. Supplement a st abilizer, adjust
to rated value.
2. Change starting relay.
3. C hange compressor.
4.The shaft and piston in the
compressor is blocked, please
change.
After short
time of
operation,
over load
protection unit
cuts off
1. The voltage is too high.
2. Over l oad protection un it i s not
good, it jumps earlier.
3. Starter contacting point is
adhered.
4. There is short circuit in
compressor.
5. There is mechanical problem in
the compressor.
6. Temperature around compressor
is too high.
1. Supplement a st abilizer and
adjust its value to rated.
2. Change ove r l oad pro tection
unit.
3. Change starting relay.
4. C hange compressor.
5. C hange compressor.
6.Increase heat radiation space.
Too m
uch
noise w
hen
compressor
runs
1. The floor is loose.
2. The w ine ce llar body is not
stable and in level.
3. When compressor runs, friction
between tubes and w ine ce llar
body causes resonance.
4. Compressor f ixing s crew i s
loose.
5. The v
ibration abso
rption
cushion for c ompressor fi xing is
too tight, or too loose or ageing.
6. Compressor inside noise is too
big or v
ibration abso rption
suspending spring is broken.
1. Reinforce the floor.
2. Make the w ine ce llar body
stable.
3. Move the tube a l ittle aw ay to
avoid friction.
4. Make the screw tight.
5. Adjust the degre e of t ight or
loose of v
ibration abso rption
cushion, or change cushion.
6. C hange compressor.
Electricity
leakage o
f
wine cel
lar
body, you w ill
feel t
ingle
when touching
by hand
1. Wine cellar body has not been
connected to the ground.
2. The c
ompressor term inal
contacts body she ll and ca uses
short circuit.
3.When the com
ponents of
electrical system get wet, insulation
ability is dropped, electricity leaks.
1. Make the ground connection as
stipulated.
2. C hange compressor.
3. C heck c arefully step by step , if
insulation is se riously d amaged,
please cha nge; remove w et p arts
and p ut th em i nto drying box to
make them dry.
Содержание JC-398G
Страница 15: ...14 System flow scenograph ...
Страница 17: ...16 2 Connect di agram ...
Страница 23: ...22 Trouble shooting 1 Compressor does t start ...
Страница 26: ...28 ...