background image

Maintenance

For Smart Use of The Air Conditioner

Setting of proper room
temperature

Close doors and windows
during operation

If the unit is not to be used
for a long time, turn off the
power supply main switch.

Use the timer effectively

Use the louvers effectively

Do not block the air inlet
or outlet

Proper
temperature

During cooling operation
prevent the penetration of
direct sunlight with
curtain or blind

OFF

Air Filter cleaning

Open the inlet grille by pulling it upward.

Remove the filter.

Clean the filter.

Attach the filter.

Close the inlet grille.

Push up the filter's center tab slightly until it is released
from the stopper, and remove the filter downward.

Use a vacuum cleaner to remove dust, or wash the filter with
water.After washing, dry the filter completely in the shade.

Attach the filter correctly so that the "FRONT" indication is
facing to the front.Make sure that the filter is completely
fixed behind the stopper.If the right and left filters are not
attached correctly, that may cause defects.

Remote Controller

Do not use the following for cleaning

Do not use water

wipe the controller with a

dry cloth.Do not use glass cleaner or chemical
cloth.

Gasoline,benzine, thinner or cleanser may
damage the coating of the unit.

Hot water over 40

O

C(104

O

F) may cause

discoloring or deformation.

Wipe the air conditioner by using a soft and
dry cloth.For serious stains,use a neutral
detergent diluted with water.Wring the water
out of the cloth before wiping.then wipe off
the detergent completely.

Indoor Body

Once every
two weeks

1.Open the lnlet Grille

2.Detach the standard air filter

3.Attach Air Purifying Filter

4.Attach the standard air filter

(Necessary installation)

5.Close the Inlet Grille

Close the Grille surely

Slide the knob slightly upward to 
release the filter, then withdraw it.

Put air purifying filter appliances into the
right and left filter frames.

Detach old Air Purifying Filter

NOTE:

The photocatalyst air purifying filter will be solarized in fixed

time. In normal family, it will be solarized every 6 months.

Prop up the inlet grille by using a

 small device named grille-support 

ATTENTION:
The white side of the photocatalyst air purifying

filter face outside,and the black side face the unit.

The green side of the bacteria-killing medium air 

and the white side face the unit.

Please keep the bacteria-killing medium air purifying filter in

avoid long time directly sunshine

when you stop using it,or its ability of sterilization will be

.

The bacteria-killing medium air purifying filter will be used 
for a long time,no need for replacement. But in the period 
of using them ,you should remove the dust frequently by 

Replacement of Air Purifying Filter

which located in the right side of

 the indoor unit. 

purifying filter face outside,

using vacuum cleaner or flaping them lightly,otherwise ,

its performance will be affected. 

the cool and dry conditions

6

reduced.

Содержание HSU-30HEA03/R2(DB)

Страница 1: ...e using the air conditioner 0010521199 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Keep this operation manual for future reference Contents 2 3 6 7 1 CAUTIONS PARTS AND FUNCTIONS OPERATION MAINTENANCE TROUBLE SHOOTING HSU 30HEA03 R2 DB ...

Страница 2: ...se change batteries If the remote controller can t run normally during operation please reload several minutes later batte remove the batteries and Remove the batteries in case unit won t be in usage for a long period If there are any display after taking out just need to press reset key Hint POWER SOFT The following functions and related displays are not 20 available Operation mode AUTO FAN COOL ...

Страница 3: ...left and right direction referring to Fig 2 Left and right air flow adjustment manual Cautions When adjusting the flap by hand turn off the unit When humidity is high condensate water might occur adjusted to left or It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY otherwise condensate water might occur conditioner temperature is below 16 o C do not use...

Страница 4: ...n for further 3 hours then stops Temp is lower than temp setting so that room temperature won t be too high for your sleep In AUTO mode The unit operates in corresponding sleep mode adapted to the automatically selected operation mode 4 In FAN mode It has no SLEEP function Note When TIMER function is set the sleeping function can t be set up After the sleeping function is set up if user resets TIM...

Страница 5: ...mantling of the air EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS In accordance with the directive 2002 96 CE of the European parliament herewith we inform the consumer about the dis posal requirements of the electrical and electronic products conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and natio...

Страница 6: ...t and dry cloth For serious stains use a neutral detergent diluted with water Wring the water out of the cloth before wiping then wipe off the detergent completely Indoor Body Once every two weeks 1 Open the lnlet Grille 2 Detach the standard air filter 3 Attach Air Purifying Filter 4 Attach the standard air filter Necessary installation 5 Close the Inlet Grille Close the Grille surely Slide the k...

Страница 7: ...ENT PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is r...

Страница 8: ...fuse of indoor unit on PC board is change it with the type of T 3 15A 250V outdoor unit is broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver Do not allow children to play with the air conditioner case should children be allowed to sit on the outdoor unit The refrigerating circuit is leak proof 1 Applica...