Operation

   Air Flow Direction Adjustm

AUTO

COOL

DRY

FAN

HEAT

2.Select operation mode

Press FAN button. For each press, fan speed changes as
follows:

Press MODE button. For each press, operation mode
changes as follows:

Remote controller:

Remote controller:

Select a desired temperature.

4.Fan speed selection

Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.

LOW

MED

HI

AUTO

1. Unit start

 Press ON/OFF on the remote controller, unit starts.

Base  Operation

Remote controller

Operation

Mode

AUTO

Display Board

Remote

Controller

Note

COOL

DRY

HEAT

FAN

nothing

In DRY mode, when room temperature becomes
lower than temp.2

o

C,unit will run intermittently

at LOW speed regardless of FAN setting.

Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according
to room temperature.

air conditioner automatically adjusts the fan speed 

temperature.

When FAN is set to AUTO, the 

according to room

In FAN operation mode, the unit will not operate in
COOL or HEAT mode but only in FAN mode ,AUTO is
not available in FAN mode.And temp.setting is disabled.
In FAN mode,SLEEP operation is not available.

Vertical flap

Pos.1

Pos.2

Pos.3

Pos.4

Pos.5

Pos.6

(Auto swing)

1.Status display of air sending

When restart after remote turning off, the remote 

         memorize the previous 

Move the vertical blade by a knob on air

to adjust left and right direction referring to Fig.

2.Left and right air flow adjustment(manual)

Cautions:

When adjusting the flap by hand,turn off the unit.

When humidity is high,condensate water might occur 

adjusted to left or 

It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY

otherwise, condensate water might occur.

conditioner

temperature is below 16

o

C, do not use it in the 

Test operation:

Use this switch in the test operation when the room

normal operation.

 your finger from the switch: the cooling

Continue to press the test operation 
switch for more than 5 seconds. After

 you hear the "Pi" sound twice, release

Test operation switch is the same as emergency switch.

operation starts with the air flow speed "Hi".

Pi Pi

at air outlet if all vertical louvers are 

right.

mode ,

controller will automatically

Note:

set swing position.

POWER/SOFT

Emergency Operation:

Emergency operation and test operation

Pi

Use this operation only when the 
remote controller is defective or lost.
When the emergency operation 
switch is pressed, the" Pi "sound is 
heard once, which means the start
of this operation.
In this operation, the system 
automatically selects the operation modes, cooling or 
fan or heat, according to the room temperature.

When machine is running in emergency, the set value 
of temperature and wind speed couldn't be altered;
meanwhile, it can't operate for dehumidifying or under
timing mode.

Press

button

Every time the button is pressed, temp.setting
increase 1

o

C,if kept depressed, it will increase

rapidly

Every time the button is pressed, temp.setting

decrease 1

o

C,if kept depressed, it will decrease

rapidly

3.Select temp.setting

Содержание HSU-30HEA03/R2(DB)

Страница 1: ...e using the air conditioner 0010521199 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Keep this operation manual for future reference Contents 2 3 6 7 1 CAUTIONS PARTS AND FUNCTIONS OPERATION MAINTENANCE TROUBLE SHOOTING HSU 30HEA03 R2 DB ...

Страница 2: ...se change batteries If the remote controller can t run normally during operation please reload several minutes later batte remove the batteries and Remove the batteries in case unit won t be in usage for a long period If there are any display after taking out just need to press reset key Hint POWER SOFT The following functions and related displays are not 20 available Operation mode AUTO FAN COOL ...

Страница 3: ...left and right direction referring to Fig 2 Left and right air flow adjustment manual Cautions When adjusting the flap by hand turn off the unit When humidity is high condensate water might occur adjusted to left or It is advisable not to keep horizontal flap at downward position for a long time in COOLor DRY otherwise condensate water might occur conditioner temperature is below 16 o C do not use...

Страница 4: ...n for further 3 hours then stops Temp is lower than temp setting so that room temperature won t be too high for your sleep In AUTO mode The unit operates in corresponding sleep mode adapted to the automatically selected operation mode 4 In FAN mode It has no SLEEP function Note When TIMER function is set the sleeping function can t be set up After the sleeping function is set up if user resets TIM...

Страница 5: ...mantling of the air EUROPEAN REGULATIONS CONFORMITY FOR THE MODELS In accordance with the directive 2002 96 CE of the European parliament herewith we inform the consumer about the dis posal requirements of the electrical and electronic products conditioning system treatment of the refrigerant of oil and of other part must be done by a qualified installer in accordance with relevant local and natio...

Страница 6: ...t and dry cloth For serious stains use a neutral detergent diluted with water Wring the water out of the cloth before wiping then wipe off the detergent completely Indoor Body Once every two weeks 1 Open the lnlet Grille 2 Detach the standard air filter 3 Attach Air Purifying Filter 4 Attach the standard air filter Necessary installation 5 Close the Inlet Grille Close the Grille surely Slide the k...

Страница 7: ...ENT PROHIBITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is r...

Страница 8: ...fuse of indoor unit on PC board is change it with the type of T 3 15A 250V outdoor unit is broken change it with the type of T 25A 250V Do not obstruct or cover the ventilation conditoner Do not put fingers inlet outlet and swing louver Do not allow children to play with the air conditioner case should children be allowed to sit on the outdoor unit The refrigerating circuit is leak proof 1 Applica...