Indoor unit

Fixing the indoor unit body

[Other direction piping]

Indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape.

Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according

to the position of wall hole. When bending, be careful not to crash pipes.

Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation

of connecting part specially.

Hang surely the unit body onto the upper notches of the

mounting plate. Move the body from side to side to verify

its secure fixing.

In order to fix the body onto the mounting plate,hold up

the body aslant from the underside and then put it down

perpendicularly.

1. Insert the drain hose into the dent of heat insulation materials of indoor unit.

2. Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then

    connect them.

3. Coat the flaring seal face with refrigerant oil and connect pipes.

    Cover the connection part with heat insulation materials closely, and make sure fixing with adhesive tape

4

Heat insulation

material

Drain hose

Piping

Indoor/outdoor

electric cable

Lid for right piping

Lid for under piping

Lid for left piping

Fix with adhesive tape

Easily-demount cleaning of indoor unit

 Inlet grille can be taken down

mounting plate

Open the inlet grille,press the button of unlock in the left,then push

it out of the socket and take out the inlet grille.

Unloading of indoor unit body

When you unload the indoor unit,please use your hand to arise
the body to leave agraffe,then lift the bottom of the body outward

slightly and lift the unit aslant until it leaves the mounting plate.

agraffe

mounting plate

Содержание HSU-18HEA03(T3)

Страница 1: ...Piping hole cover Arrangement of piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance between the indoor unit and the floor shoul...

Страница 2: ...s can be left In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by...

Страница 3: ...ticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a...

Страница 4: ...o the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring se...

Страница 5: ...lease change it with the type of T 3 15A 250V 3 The wiring method should be in line with the local wiring standard 4 After installation the power plug should be easily reached 5 When connecting the ca...

Страница 6: ...he screws If wiring is not correct proper operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for...

Страница 7: ...torque Valve rod Valve cap 7 9 20 25 Tighten torque N m When connecting pipe exceeds 5 meters 20g refrigerant shall be added per exceeding meter Charge according to the following list Piping length A...

Страница 8: ...r in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Pleas...

Отзывы: