background image

Fixing of outdoor unit

Indoor Unit

Selection of Installation Place

Power Source

Selection of pipe

Outdoor Unit

Fix the unit to concrete or block with bolts(   10mm) and nuts firmly and horizontally.

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Place, robust not causing vibration, where the body can be supported

sufficiently.

Place, not affected by heat or steam generated in the vicinity, where

inlet and outlet of the unit are not disturbed.

Place, possible to drain easily, where piping can be connected with the

outdoor unit.

Place, where cold air can be spread in a room entirely.

Place, nearby a power receptacle, with enough space around. (Refer

to drawings).

Place where the distance of more than lm from televisions, radios,

wireless apparatuses and fluorescent lamps can be left.

In the case of fixing the remote controller on a wall, place where the

indoor unit can receive signals when the fluorescent lamps in the room

are lightened.

Place, which is less affected by rain or direct sunlight and is

sufficiently ventilated.

Place, possible to bear the unit, where vibration and noise are

not increased.

Place, where discharged wind and noise do not cause a

nuisance to the neighbors.

Place, where a distance marked       is available as illustrated

in the above figure.

Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.

2

Liquid pipe ( )

Gas pipe   (    )

For  18

6.35mm(1/4")

12.7mm(1/2")

HSU-18HEA13(T3)

Floor fixing dimensions

of the outdoor unit

(Unit:mm)

140

500

140

65

2

HSU-18HEA03(T3)

Содержание HSU-18HEA03(T3)

Страница 1: ...Piping hole cover Arrangement of piping directions Rear left Rear right Left Below Right The marks from to in the figure are the parts numbers The distance between the indoor unit and the floor shoul...

Страница 2: ...s can be left In the case of fixing the remote controller on a wall place where the indoor unit can receive signals when the fluorescent lamps in the room are lightened Place which is less affected by...

Страница 3: ...ticle When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a...

Страница 4: ...o the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then connect them 3 Coat the flaring se...

Страница 5: ...lease change it with the type of T 3 15A 250V 3 The wiring method should be in line with the local wiring standard 4 After installation the power plug should be easily reached 5 When connecting the ca...

Страница 6: ...he screws If wiring is not correct proper operation can not be carried out and controller may be damaged If the drain elbow is used please attach it as figure Note Only for heat pump unit Drawing for...

Страница 7: ...torque Valve rod Valve cap 7 9 20 25 Tighten torque N m When connecting pipe exceeds 5 meters 20g refrigerant shall be added per exceeding meter Charge according to the following list Piping length A...

Страница 8: ...r in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Pleas...