Air conditioner is running under displayed fan speed.
In DRY mode, when room temperature becomes
lower than temp.2

o

C,unit will run intermittently 

at LOW speed regardless of FAN setting.

2.Select operation mode

Press FAN button. For each press, fan speed changes as
follows:

Press MODE button. For each press, operation mode
changes as follows:

Remote controller:

Remote controller:

Then Select DRY operation

Press TEMP. button

Every time the button is pressed, temp.setting 
increase 1

o

C,if kept depressed, it will increase 

rapidly

Every time the button is pressed, temp.setting 
decrease 1

o

C,if kept depressed, it will decrease 

rapidly

Select a desired temperature.

4.Fan speed selection

3.Select temp.setting

5.Unit stop

Press ON/OFF button, the unit stops.

COOL operation starts when room
temp.is higher than temp.setting.

On reaching temp.s2

o

C

unit will run in mild DRY mode.

Ultra-low air flow

Temp.2

o

C

Temp.setting

AUTO

LOW

MED

HI

AUTO

COOL

DRY

FAN

HEAT

Operation

Dry Operation

1. Unit start

 Press ON/OFF on the remote controller, unit starts.

Remote controller

11

STERILIZE

FRESH

Содержание HSU-18CV03(T3)

Страница 1: ...No 0010556977 SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL Please read this operation manual before using the air conditioner HSU 18CV03 T3 HSU 24CV03 T3...

Страница 2: ...disposal services nearest to your house Disposal of the packaging of your new air conditioner Before starting the air conditioner read the information given in the User s Guide caref ully The User s G...

Страница 3: ...ne is adaptive in following situation 10 The power plug and connecting cable must have acquired the local attestation 2 If the power supply cord is damaged it must be replaced by the manufacturer or i...

Страница 4: ...e Please call Sales Service Shop for the Installation Do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage lnstallation in a ina...

Страница 5: ...ially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occ...

Страница 6: ...d Inlet Air Purifying Filter Vertical flap adjust up and down air flow Don t adjust it manually Horizontal louver Air filter inside Inlet grille Power plug adjust left and right air flow inside Outlet...

Страница 7: ...w display Remote controller to display the TEMP setting 22 TEMP display 23 TIMER OFF display 24 CLOCK display 25 TEMP button Used to select fan speed LOW MED HI AUTO 26 FAN button Used to set the heal...

Страница 8: ...e as well Don t throw or knock the remoter controller When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is...

Страница 9: ...no TiO2 on the multi lights touching intermediary and the degerming effect is highly efficient and lasting Note when the function is running don t open the inlet grille About UV light degerming functi...

Страница 10: ...roller Then Select Auto operation AUTO COOL DRY FAN HEAT Press FAN button For each press fan speed changes as follows Remote controller Press TEMP button Every time the button is pressed temp setting...

Страница 11: ...it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp settin...

Страница 12: ...n is pressed temp setting increase 1o C if kept depressed it will increase rapidly Every time the button is pressed temp setting decrease 1o C if kept depressed it will decrease rapidly Select a desir...

Страница 13: ...Fan speed selection 4 Unit stop About FAN operation In FAN operation mode the unit will not operate in COOL or HEAT mode but only in FAN mode AUTO is not available in FAN mode And temp setting is dis...

Страница 14: ...ease 1o C if kept depressed it will decrease rapidly Select a desired temperature 4 Fan speed selection 3 Select temp setting 5 Unit stop Press ON OFF button the unit stops AUTO LOW MED HI AUTO COOL D...

Страница 15: ...The vertical flap will swing according to the above positions HEAT AUTO 1 Status display of air sending Horizontal louvers Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Pos 6 Pos 7 Pos 8 3 Left and right air flow dir...

Страница 16: ...tting so that room temperature won t be too Iow for your sleep Remote Controller SLEEP operation starts SLEEP operation stops SLEEP operation starts SLEEP operation stops Approx 6hrs 1 hr 1 hr 1 hr 3...

Страница 17: ...ressed display changes as follows Remote controller BLANK TIMER ON TIMER OFF TIMER ON OFF Then select your desired TIMER mode TIMER ON or TIMER OFF or will flash 3 Time setting Press HOUR button Every...

Страница 18: ...OFF will flash 3 Time setting Press HOUR button Every time the button is pressed time setting increases 1 min if kept depressed it will increase rapidly Every time the button is pressed time setting...

Страница 19: ...tting the health airflow function the position of inlet and outlet grills is fixed 2 In heating it is better to select the mode 3 In cooling it is better to select the mode 4 In cooling and dry using...

Страница 20: ...in the test operation when the room temperature is below 16 O C do not use it in the normal operation Continue to press the test operation switch for more than 5 seconds After you hear the Pi sound t...

Страница 21: ...tion If the unit is not to be used for a long time turn off the power supply main switch Use the timer effectively Use the louvers effectively Do not block the air inlet or outlet Maintenance Proper t...

Страница 22: ...etely fixed behind the stopper If the right and left filters are not attached correctly that may cause defects Remote Controller Do not use the following for cleaning Do not use water wipe the control...

Страница 23: ...t of the bacteria killing medium air purifying filter will face outside the white aspect will face to the machine NOTE The photocatalyst air purifying filter and the bacteria killing medium air purify...

Страница 24: ...for 2 3 hours Put off the power supply cord Take out the batteries from the wireless remote controller Cleaning the body To prevent breeding mold or bad smell be sure to operate at the designated tem...

Страница 25: ...e plug insert the plug of the power supply cord into the outlet completely In case of suing exclusive circuit breaker switch on the circuit breaker NO WET HAND EARTHING Operation without filter may ca...

Страница 26: ...ve elapsed to protect the system When the electric plug is pulled out and reinserted the protection circuit will work for 3 minutes to protect the air conditioner During unit operation or at stop a sw...

Отзывы: