background image

Indoor unit

5

5.Easily-demount cleaning of indoor unit

1.Top inlet can be taken down

Open the inlet grille, press the claw of the clip on the unit,then
take down the top inlet.(according to figure 1)

claw of the clip

 Figure 1

 Figure 2

 Figure 3

2.Vertical flap can be taken down

Overturn the vertical flap, press the claw of the clip ,then take
down vertical flap.(according to figure 2)

3.Horizontal louvers can be taken down

After taking down vertical flap.Horizontal louvers are appeared,draw
the middle louver,and take down the horizontal louvers .
(according to figure 3)

 Figure 2

Daff

When connecting the cable before installing the indoor unit

Insert the cable from the back side of the unit, then pull it out on the front side.

Loosen the screws and insert the cable ends fully into terminal block, then tighten the screws.

Pull the cable slightly to make sure the cables have been properly inserted and tightened.

After the cable connection, never fail to fasten the connected cable with the wiring cover.

Note: When connecting the cable, confirm the terminal number of indoor and outdoor units carefully.

       If wiring is not correct, proper operation can not be carried out and will cause defect.

Indoor unit

Outdoor unit

Indoor unit

Outdoor unit

POWER PLUG

HSU-07HV03/R2(DB)
HSU-09HV03/R2(DB)
HSU-12HV03/R2(DB)
HSU-18HV03/R2(DB)
HSU-12HVB03/R2(DB)

HSU-22HV03/R2(DB)

L

N

{

Power cable:
-mod 07-09-12: 3G1.5mm

2

-mod 18-22: 3G2.5mm

2

HSU-18HVA103/R2(DB)

HSU-22HVA103/R2(DB)

HSU-07HVA103/R2(DB)
HSU-09HVA103/R2(DB)
HSU-12HVA103/R2(DB)

Содержание HSU-07HVA103

Страница 1: ...e 9 Nipper 12 Reamer 10 Gas leakage detector or soap and water solution 11 Measuring tape Explain sufficiently the operating means to the user according to this manual A G G F A C D E No Accessory par...

Страница 2: ...ated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where a distance marked is availab...

Страница 3: ...article When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make...

Страница 4: ...the underside and then put it down perpendicularly Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable after instal...

Страница 5: ...e cable from the back side of the unit then pull it out on the front side Loosen the screws and insert the cable ends fully into terminal block then tighten the screws Pull the cable slightly to make...

Страница 6: ...neer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then charge additional refrigerant Use the same method on indoor unit Loose...

Страница 7: ...steps Detach the charge hose from the service port open 2 way valve and 3 way Turn the valve rod anticlockwise until hitting lightly To prevent the gas leakage turn the service port s cap the valve ro...

Страница 8: ...ried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that draina...