Fixing of outdoor unit

Indoor Unit

Selection of Installation Place

Power Source

Selection of pipe

Outdoor Unit

Fix the unit to concrete or block with bolts(   10mm) and nuts firmly and horizontally.

When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.

If vibration may affect the house, fix the unit by attaching a vibration-proof mat.

Place, robust not causing vibration, where the body can be supported
sufficiently.
Place, not affected by heat or steam generated in the vicinity, where
inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the
outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer
to drawings).
Place where the distance of more than lm from televisions, radios,
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.

Place, which is less affected by rain or direct sunlight and is
sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are
not increased.
Place, where discharged wind and noise do not cause a
nuisance to the neighbors.
Place, where a distance marked       is available as illustrated
in the above figure.

Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.

Install an exclusive branch circuit of the power.

A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.

To this unit, both liquid and gas pipes shall be insulated

as they become Iow temperature in operation.

Use optional parts for piping set or pipes covered with

equivalent insulation material.

The thickness of the pipe must be 0.8 mm at least.

Liquid pipe(     )

Gas pipe(     )

Floor fixing dimensions
of the outdoor unit
(Unit:mm)

500

140

140

256

583

113.5

113.5

319.5

Floor fixing dimensions
of the outdoor unit
(Unit:mm)

2

6.35mm(1/4")

9.52mm(3/8")

6.35mm(1/4")

12.7mm(1/2")

HSU-07HV03/R2(DB)

HSU-09HV03/R2(DB)

HSU-12HV03/R2(DB)
HSU-18HV03/R2(DB)
HSU-22HV03/R2(DB)

HSU-12HVB03/R2(DB)

HSU-18HVA103/R2(DB)
HSU-22HVA103/R2(DB)

HSU-07HVA103/R2(DB)

HSU-09HVA103/R2(DB)

HSU-12HVA103/R2(DB)

HSU-09HV03/R2(DB)
HSU-12HV03/R2(DB)

HSU-07HV03/R2(DB)

HSU-18HV03/R2(DB)

HSU-22HV03/R2(DB)

HSU-12HVB03/R2(DB)

HSU-18HVA103/R2(DB)

HSU-22HVA103/R2(DB)

HSU-09HVA103/R2(DB)
HSU-12HVA103/R2(DB)

HSU-07HVA103/R2(DB)

Содержание HSU-07HVA103

Страница 1: ...e 9 Nipper 12 Reamer 10 Gas leakage detector or soap and water solution 11 Measuring tape Explain sufficiently the operating means to the user according to this manual A G G F A C D E No Accessory par...

Страница 2: ...ated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where a distance marked is availab...

Страница 3: ...article When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make...

Страница 4: ...the underside and then put it down perpendicularly Remove terminal cover at right bottom corner of indoor unit then take off wiring cover by removing its screws When connecting the cable after instal...

Страница 5: ...e cable from the back side of the unit then pull it out on the front side Loosen the screws and insert the cable ends fully into terminal block then tighten the screws Pull the cable slightly to make...

Страница 6: ...neer Before adding additional refrigerant perform air purging from the refrigerant pipes and indoor unit using a vacuum pump then charge additional refrigerant Use the same method on indoor unit Loose...

Страница 7: ...steps Detach the charge hose from the service port open 2 way valve and 3 way Turn the valve rod anticlockwise until hitting lightly To prevent the gas leakage turn the service port s cap the valve ro...

Страница 8: ...ried out Please install the drain hose so as to be downward slope without fail Please don t do the drainage as shown below Please pour water in the drain pan of the indoor unit and confirm that draina...

Отзывы: