7-5.
Location of your dryer
SERVICE MANUL
Model No.HLTD500ACW
Issue
Rev.
- 16 -
Dryers being installed in a manufactured (mobile) home MUST employ a 4-
wire power supply cord NEMA 14-30 type SRDT or ST (as required) rated to
240 Volt AC minimum, 30 Amp, with 4 open-end spade lug connectors with
upturned ends or closed loop connectors and marked for use with clothes
dryers. See Electrical Connections for more information on a 4-wire system.
Do Not Install Your Dryer:
1. In an area exposed to dripping water or outside weather conditions.
2. In an area where it will come in contact with curtains, thick carpet, or
anything that will obstruct the flow of combustion and ventilation air.
3. On carpet, floor must be solid with a maximum slope of 1inch (2.54 cm).
Any floor unevenness should be corrected with leveling legs located on the
bottom of the dryer.
Installation in Alcove or Closet:
1.
DO NOT
install your dryer in a closet with a solid door.
2. A dryer installed in a bedroom, bathroom, alcove or closet MUST be
exhausted outdoors.
3. No other fuel burning appliance shall be installed in the same closet as the
gas dryer.
Outlet Receptacle
NEMA 10-30R receptacle should be located so the power supply cord is
accessible when the dryer is in the installed position. (Canada - NEMA
14-30R receptacle)
4. Refer to the images on this page to ensure the installation provides the
minimum amount of clearance required for ventilation.
5. When installing the dryer in a closet with a door, a minimum of 120 square
inches (774.2 square cm) of ventilation in the door is required. Openings
must be equally divided at the top and bottom of the door and airflow must
be unobstructed. A louvered door with equivalent air openings for the length
of the door is acceptable.