7
Installation instructions
Installing a thermal protection barrier
Important!
If the cooktop is installed over drawers or cupboards and its underside surface thus becomes accessible
after installation, a thermal protection barrier must be fitted at least 30 mm beneath the base of the
cooktop (see Fig. 3). This barrier must be made of low thermal conductivity material installed according to
the instructions for installation.
Note:
The requirement above is not applicable if the cooktop is installed directly above an oven.
For access to the cooktop for servicing or installation, ensure that the barrier can be removed from
beneath.
A gap of 20 mm may be allowed at the rear of the barrier (see Fig.4) for electrical connection and
ventilation.
20 mm gap
30 mm
Fig. 3 Minimum clearance for thermal
protection barrier
Thermal protection barrier
(min. 15 mm thick)
This must be fitted for the full length of the cook-
top below the bench, and be removable for
installation and service.
Fig. 4 Side sectional view