How do I replace an empty C02 tank?
1. Close tank drum valve by turning clockwise.
2. Unscrew adjustment Set Screw (counter-clockwise) as far as it will go and close
shut off valve.
3. Remove regulator from empty tank.
4. Remove dust cap from the new full tank. Open and close drum valve quickly
to blow of the dust from the outlet.
5. With drum valve in closed position, reattach regulator to the tank. Be sure to
check the washer, which is pre-installed on the C02 regulator.
6. Open drum valve all the way. (This is important because this drum valve seals
in two places.)
7. Readjust regulator pressure by turning set screw and open shut off valve.
Tank Information: Tank must always be fastened in the upright position.
It takes about 1/2 lb. of C02 to dispense 1/2 barrel keg of
beer. A 5 lb. C02 tank should dispense between 8-10 1/2
barrel kegs or 18-20 1/4 barrel kegs. Full weight of 5 lb. tank
is appx. 17-1/2 lbs.