– 9 –
Specifications Gas Models
DC Voltage Output
Board
Component
Connector Pin
DC Volts
Dryer Main
Control Board
User Interface
J601
8
13.5
2
GND
Outlet Thermistor
J302
1
5
2
GND
Inlet Thermistor
J302
3
5
4
GND
RJ45
J302
5
13.5
8
GND
LED Lamp
J303
1
5
3
GND
Wi-Fi
J604
1
5
5
GND
Dryer User
Interface Board
UI
J101
5
13.5
4
GND
Dryer Wi-Fi
Board
Wi-Fi
J103
1
5
5
GND
Windings and Coils
Resistance Values (
W)
Main Motor
Normal Vent
Models
Run
2.84 to 3.27
Start
2.82 to 3.12
Main Motor
Long Vent
Models
Run
2.72 to 3.12
Start
2.25 to 2.48
Gas Valve
Main
1135 to 1595
Booster
460 to 660
Safety
1095 to 1555
Igniter
-
40 to 400 @ 75°F
Water Valve
-
891-1089
Thermistors Resistance Values (
W)
K OHMS
TEMP.
°F
TEMP.
°C
76 to 84
86
30
95 to 105
77
25
118 to 132
68
20
Thermostat
TEMP.
°F
TEMP.
°C
Open Close Open Close
Outlet
Control
Backup
165
155
74
68
Inlet Control
Backup
221
200
105
93
High Limit
302 -31 or
below 150
-35 or
below
Safety
190
151
88
66