– 56 –
Fault Codes
Fault
Code
Description
Trigger Condition
Action
1
Inlet Thermistor
Failure
Thermistor readings are
out of range.
• Check harness and connections. If
good, replace thermistor.
2
Outlet
Thermistor
Failure
Thermistor readings are
out of range.
• Check harness and connections. If
good, replace thermistor.
6
Stuck Button
If a button is depressed
for 1 minute, it will be
logged as a stuck button.
• Check and replace the user interface
(UI) board if necessary.
7
Miss Wire
L2/N are mis-wired.
• L2 and N need to be rewired. The
display will show "E7".
8
Door Latch
Stuck
If five cycles are run and
the DOOR_LATCH_
SIGNAL has not gone
open, then this error is
set.
• Check and replace door switch and/or
harness, if necessary.
9
Dry Load
Detection Trip
The dry load detection
algorithm has been
tripped.
• Check and replace outlet/inlet
thermistor, if necessary.
10
Empty Drum
Detection
Tripped.
Empty drum detection
algorithm has been
tripped.
• Check and replace sensor rods and/or
harness, if necessary.
11
Blocked Vent
The blocked vent
algorithm has detected a
blockage.
• Check the vent and clear, if blocked.
13
Door Switch
Signal Stuck
Closed
If five cycles are run and
the DOOR_STATE signal
in the hardware door
switch detection circuit
has not gone open, then
this error is set.
• Check and replace door switch,
harness and/or main board, if
necessary.
14
Door Latch
Pulsing Error
Malfunction of door switch
detection circuit.
• Check and replace door switch,
harness and/or main board, if
necessary.
15
Critical Flood
Level by Gallons
Malfunction of door switch
detection circuit.
• Check and replace door switch,
harness and/or main board, if
necessary.
19
Door Latch Lost
In Run
This can happen during
normal operation when
power brownout occurs.
• If the issue is persistently happening,
replace the main board.