– 53 –
Service Mode Tests
Test
No.
Test Name
Description
0
All LED’s On
All LED's on the display will blink including "88" on the Seven Segment
Display (SSD) at a rate of 1Hz
1
Fault Codes
•
Pressing Start pad will blink the first fault code.
• Press the Start button to advance to the next fault.
•
At end of list, OR if no fault codes are present, unit will flash "- -".
• Pressing Start again at the end of the list will wrap back around to display
the first fault again.
• Rotate the cycle knob to end the current test and advance to the next test.
2
Personality ID
• Pressing Start/Pause will start the test.
• Flash the set personality after pressing Start.
• Use Seven Segment Display (SSD) to show personality.
• Rotate the cycle knob to end the current test and advance to the next test.
3
MC Software
Version
(Critical)
• Press Start to toggle through software version number as follows
(Example v01.23).
• First Press: "01" on Seven Segment Display (SSD).
Major Version (Pause LED will be ON).
• Second Press: "23" on Seven Segment Display (SSD).
Minor Version (Sensing LED will be ON).
• Rotate the cycle knob to end the current test and advance to the next test.
4
MC Application
Version (Non-
Critical)
• Press Start to toggle through software version number as follows
(Example v01.23).
• First Press: "01" on Seven Segment Display (SSD).
Major Version (Pause LED will be ON).
• Second Press: "23" on Seven Segment Display (SSD).
Minor Version (Sensing LED will be ON).
• Rotate the cycle knob to end the current test and advance to the next test.
5
MC Parametric
Version (Non-
Critical)
• Press Start to toggle through software version number as follows
(Example v01.23).
• First Press: "01" on Seven Segment Display (SSD).
Major Version (Pause LED will be ON).
• Second Press: "23" on Seven Segment Display (SSD).
Minor Version (Sensing LED will be ON).
• Rotate the cycle knob to end the current test and advance to the next test.
6
User Interface
Software
Version
(Critical)
• Press Start to toggle through software version number as follows
(Example v01.23).
• First Press: "01" on Seven Segment Display (SSD).
Major Version (Pause LED will be ON).
• Second Press: "23" on Seven Segment Display (SSD).
Minor Version (Sensing LED will be ON).
• Rotate the cycle knob to end the current test and advance to the next test.
7
User Interface
Software
Version (Non-
Critical)
• Press Start to toggle through software version number as follows
(Example v01.23).
• First Press: "01" on Seven Segment Display (SSD).
Major Version (Pause LED will be ON).
• Second Press: "23" on Seven Segment Display (SSD).
Minor Version (Sensing LED will be ON).
• Rotate the cycle knob to end the current test and advance to the next test.
(
Continued next page
)