Page 3
31-5000727 Rev. 0
Technical Specifications - NF96DV
MODEL NUMBER GUIDE
PHYSICAL AND ELECTRICAL DATA
Model
1st Stage
2nd Stage
AFUE
(ICS)
Nominal
Cooling
Capacity
Gas
Inlet
(in.)
Volts/
Hz/
Phase
Max. Time
Delay
Breaker
or Fuse
Nominal
F.L.A.
Trans.
(V.A.)
Approx.
Shipping
Weight
(lbs.)
Input
(Btuh)
Output*
(Btuh)
Input
(Btuh)
Output*
(Btuh)
DOWNFLOW
NF96D070V4B
43,000 42,000 66,000
64,000
96.0
4
1/2
120-60-1
15
10.1
40
136
NF96D090V5C
57,000 56,000 88,000
85,000
96.0
5
1/2
120-60-1
20
12.8
40
164
NF96D110V5C
72,000 70,000 110,000 106,000
96.0
5
1/2
120-60-1
20
12.8
40
176
Note: For vent length and clearances to combustibles, please reference installation instructions.
* Outputs shown are High Fire, 100% rate, Low Fire is 67% of shown output.
MAJOR/MINOR REVISION
CABINET WIDTH
B - 17.5”
C - 21”
NOMINAL CFM
3 - 1200 CFM
4 - 1600 CFM
5 - 2000 CFM
DESIGN VARIANT
V - VARIABLE SPEED
BRAND
N - GE
PRODUCT
F - FURNACE, GAS
AFUE
96 = 96% EFFICIENCY
APPLICATION
D - DOWNFLOW
HEATING INPUT (1000 BTU/HR)
70, 90, 110
N
N FF 96
96 D
D
VV 55 C
C XX
XX
110
110