Page 26
31-5000727 Rev. 0
Maximum Allowable Intake or Exhaust Vent Length in Feet
Concentric Termination at Elevation 0 - 4,500 ft
Number of 90°
Elbows Used
1-1/2" Pipe
2" Pipe
2-1/2" Pipe
3" Pipe
Model
Model
Model
Model
070
090
110
070
090
110
070
090
110
070
090
110
1
n/a
n/a
n/a
43
27
7
90
74
39
106
99
99
2
38
22
n/a
85
69
34
101
94
94
3
33
17
80
64
29
96
89
89
4
28
12
75
59
24
91
84
84
5
23
7
70
54
19
86
79
79
6
18
n/a
65
49
14
81
74
74
7
13
60
44
9
76
69
69
8
n/a
55
39
n/a
71
64
64
9
50
34
66
59
59
10
45
29
61
54
54
Concentric Termination Elevation 4,501 - 10,000 ft
Number of 90°
Elbows Used
1-1/2" Pipe
2" Pipe
2-1/2" Pipe
3" Pipe
Model
Model
Model
Model
070
090
110
070
090
110
070
090
110
070
090
110
1
n/a
n/a
n/a
43
27
n/a
90
74
39
106
99
99
2
38
22
85
69
34
101
94
94
3
33
17
80
64
29
96
89
89
4
28
12
75
59
24
91
84
84
5
23
7
70
54
19
86
79
79
6
18
n/a
65
49
14
81
74
74
7
13
60
44
9
76
69
69
8
8
55
39
n/a
71
64
64
9
n/a
50
34
66
59
59
10
45
29
61
54
54
*Size intake and exhaust pipe length separately. Values in table are for Intake OR Exhaust, not combined total. Both Intake and
Exhaust must be same pipe size.
Table 10B.
Содержание GE NF96DV
Страница 51: ...Page 51 31 5000727 Rev 0 Notes...