Fault
Code
Description
Trigger Condition
Action
E11
Heating Fault
Within 15 minutes of
the heating process, the
temperature rise has not
reached 122°F (50°C) and
the minimum temperature
difference is not more than
41°F (5°C) during this period.
• Check both heaters 1 and 2 and input
voltage.
• Check harness and connector.
• Replace main board in necessary.
E12
Communication
Fault
Three (3) communication
faults between main and user
interface boards.
• Check harness, connector and DC
input voltage to the user interface
board.
• If good, replace the user interface
board.
• If User Interface (UI) board is good,
replace main board.