CONNECT SERIES SERVICE MANUAL
64
ENGLISH
Maintenance
Compressor Disassembly
Note: Be sure the refrigerant is recovered and power is isolated before removing the compressor.
Step
Picture
Work instruction
3. Break off the pipes that
connect to the compressor.
Braze the pipes that are connected to
the compressor.
Then remove the pipes.
Note: When brazing the pipes, do
not let the flame burn the other
components
4. Remove the compressor
from the chassis
Take out the compressor and replace it.
Note: When replacing the compressor,
avoid touching the nearby pipeline and
components.
5. Fix the new compressor
back onto the chassis.
After replacing the compressor,
tighten up the screws at the foot of
compressor.
Содержание GE APPLIANCES Connect Series
Страница 13: ...CONNECT SERIES SERVICE MANUAL 11 ENGLISH Troubleshooting Model AUH4860ZGDA ...
Страница 22: ...CONNECT SERIES SERVICE MANUAL 20 ENGLISH Troubleshooting AUH4860ZGDAA ...
Страница 84: ...CONNECT SERIES SERVICE MANUAL 82 ENGLISH Maintenance AUH4860ZGDA ...
Страница 86: ...CONNECT SERIES SERVICE MANUAL 84 ENGLISH Maintenance IDU Exploded View and Parts Lists UUY24ZGDAA UUY36ZGDAA ...
Страница 96: ...CONNECT SERIES SERVICE MANUAL ENGLISH Appendices 94 ...
Страница 97: ...CONNECT SERIES SERVICE MANUAL 95 ENGLISH Appendices ...
Страница 98: ...CONNECT SERIES SERVICE MANUAL 96 ENGLISH Appendices ...
Страница 99: ...CONNECT SERIES SERVICE MANUAL 97 ENGLISH Appendices ...
Страница 101: ......