CONNECT SERIES SERVICE MANUAL
46
ENGLISH
Maintenance
Picture
Name
Function
Compressor
Through compression, the low pressure refrigerant becomes
pressurized. As its pressure and temperature both rise, it
becomes high pressure and high temperature refrigerant. It is the
power drive of the system.
4-way valve
It is used to change the direction of refrigerant flow for heating
and cooling.
Motor
The power drive of the fan. It enables the fan to run so as to
provide air to flow across the coil and transfer heat from the coil
to the air.
Fan
It is used to provide smooth currents of air for forced convection
and heat exchange of condenser and evaporator.
Gas liquid
separator
Installed at the suction side of compressor, it can separate the
liquefied refrigerant from the gaseous refrigerant to make sure
that only gaseous refrigerant will be drawn into the compressor.
Ineffective compression or slugging phenomenon will occur if
liquid refrigerant enters the compressor.
Removal of Major Components
Removal of ODU Major Components
Содержание GE APPLIANCES Connect Series
Страница 13: ...CONNECT SERIES SERVICE MANUAL 11 ENGLISH Troubleshooting Model AUH4860ZGDA ...
Страница 22: ...CONNECT SERIES SERVICE MANUAL 20 ENGLISH Troubleshooting AUH4860ZGDAA ...
Страница 84: ...CONNECT SERIES SERVICE MANUAL 82 ENGLISH Maintenance AUH4860ZGDA ...
Страница 86: ...CONNECT SERIES SERVICE MANUAL 84 ENGLISH Maintenance IDU Exploded View and Parts Lists UUY24ZGDAA UUY36ZGDAA ...
Страница 96: ...CONNECT SERIES SERVICE MANUAL ENGLISH Appendices 94 ...
Страница 97: ...CONNECT SERIES SERVICE MANUAL 95 ENGLISH Appendices ...
Страница 98: ...CONNECT SERIES SERVICE MANUAL 96 ENGLISH Appendices ...
Страница 99: ...CONNECT SERIES SERVICE MANUAL 97 ENGLISH Appendices ...
Страница 101: ......