background image

5

6

3

4

During installation, adequate space must be reserved for future maintenance and repair (at least 300 mm). 

If the water heater is installed within decoration boards, the right board shall be removable to facilitate 

removing the plastic cover during maintenance. 
Tap water inlet pressure shall be no less than 0.05MPa and the maximum pressure shall not exceed 0.75MPa.
Electric water heater shall be installed indoors with ambient temperature above 0°C. The pipes shall be 

collectively laid. Hot water outlet shall not be too far from use points. In case farer than 8 m, hot water pipe 

shall have a thermal insulation to minimize heat loss.

load bearing walls or air brick walls must have corresponding protective measures like additional support, 

wall-through screws or back boards. 

tank or pipes leak, nearby or lower facilities shall not be damaged. The installation location shall avoid being 

above toilet bowl, bathtub, washbasin or doorframe, where will cause a suppressed or unsafe feeling to users.
Do not confuse inlet and outlet water pipes. Safety valve shall be installed at designated position with no 

Use a test pencil to check whether the live line and null line are wrongly connected. Power may only be 

connections. The power supply should also conform to the heater’s requirements.
To avoid danger caused by accidental reset of heating breaker, the power for the heater cannot be supplied by 

timer and other external switch devices or connected to circuit with frequent switching for facility use.
In order to avoid unforeseen accidents, only install components Haier-provided . Do not switch or exchange parts yourself. 

If components are damaged, you must contact the company’s repair center and use the parts supplied by Haier. If to the 

user fails to follow the requirement above, Haier will not be responsible for any direct or indirect damages caused hereof.

Installation warning

Introduction of control panel

Preset Bath Mode

Installation of remote control unit holder

Remote control unit panel

Cleaning and maintenance

Real-time Heating Mode 

C urrent Temp.

H ea ting T emp.

Norma l F a s t T urbo

S P E E D

S E T

T IM E R

kW

O n  

1

2

3

4

5
6
7

8

9

0
A

1

 

Actual temperature

2

 

Set temperature

3

 

Power

4

 

Current time

5

 

Current time/

temperature increase 

key

6

 

Power selection key

7

 

Time setting key

8

 

Heating Temp.

 

icon Blinking, 

indicates heating is in process; 

temperature is maintained at 

set temperature once it stops 

blinking.

9

 

Preset stop-heating)

0

 

Preset bath, preset stop-heating 

setting key

A

 

is water leakage at the respective joints before connecting power. Once power is connected, the panel will show full 

display for 1 second, accompanied by a buzzer sound. The heater will then enter into shutdown state as before.

Press   key to switch on the heater
Press

   

key for the heater to interchange between standby state (with clock display only) and working state.

Press 

+

 keys to set the temperature to (35~75°C)

The 

Heating Temp.

 value icon on the control panel will blink and changes correspondingly. Once 

the desired value is reached press 

SET

Press 

SPEED

 key repeatedly to select the heating power

This product provides three power settings for your selection. Low (1kW), Medium (2kW), High (3kW).

Press 

SET

 key to calibrate the clock.

Press the 

SET

+

 to set the hour; Press the 

SET

 key again, 

+

 to set the minute; After setting, press 

SET

the value blinks for 6 seconds without any further operation, the system will automatically enter next 

Under real-time heating mode, the heater will automatically heat the water or maintain the 

temperature near the set value. (If the set temperature is lower than 55°C, the heater will heat again 

once the temperature is lower than the set value by 5°C; If the set temperature is between 55°C and 

75°C, the heater will heat again once the temperature is lower than the set value by 10°C.)

This product is equipped with preset bath function. Activate the preset bath function to set the preset 

bath time, power and temperature. If no operation is carried out for 2 minutes after that, the heater will 

enter into power saving mode (display on and current time only). It will also calculate the heating time, 

and heat the water to the preset temperature automatically before the preset time.

Carry out Steps 1~4 of the real-time heating mode
Press the 

TIMER

 key, the preset bath icon on displays.

Press 

SET

 key to set the preset time

Press the 

SET

+

 to set the hour; Press the 

SET

 key again, 

+

 to set the minute; After setting, press 

SET

the value blinks for 6 seconds without any further operation, the system will automatically enter next 

Note: If the actual temperature doesn't reach the set temperature at the preset time, the heater will extend 

the heating time by 30 minutes automatically. After 30 minutes the heater will stop heating no mater 

the temperature reaches to the set temperature or not.

 

If by the preset time the actual temperature is that of the set temperature, but the actual temperature 

drops by 5°C by the preset time, the heater will re-heat the water. Once the preset time is reached, it 

will stop heating whether or not the water reaches the set temperature.

Use the correct screws in the accessories to secure the remote control unit 

holder onto a suitable position on the wall; and insert the remote control 

unit into the holder (see illustration below).

 Used to adjust the temperature value

Explanation:

 The use of the buttons on the remote control unit is the same as that for the 

buttons on the control panel.

Note:  

When using the remote control unit it is best to use it at close distance and at a 

perpendicular angle. When the battery in the remote control unit is completely 

exhausted, please remove the cover on its back using a coin to turn the knob in the 

direction as indicated, then remove the button battery inside and replace it with 

prevent explosion. They should be disposed of in accordance with regulations.

Warning

maintenance may cause severe injury or damage.
Disconnect power supply before cleaning. Gently wipe with wet cloth dipped with a little of 

mild detergent. Do not use gasoline or other solvents. Finally dry with dry cloth. Keep water 

heater dry. Do not use cleansers containing grinding agent (e.g. toothpaste), acids, chemical 

elements and tank liner of water heater shall be cleaned once in three years. Take care not 

to damage protection layer on heating elements and tank liner inner surface. According to 

maintenance is needed, please contact local service station.

Friendly reminder: 

1. In long-term out-of-use or maintenance of the heater, you can close the city water pipe 

valve and set the mixing valve to the highest water temperature rate after opening the 

safety valve handle. Move up the safety valve handle to drain the tank.

switching on the water heater, exhausting gas possibly retained in the pipeline. In this case, 

in good condition.

1

2

2

1

4

3

Preset Stop-heating Mode

This product is also equipped with preset stop-heating  mode, i.e. the heater will automatically stop-heating  

at the appointed time.

Carry out Steps 1~4 of the real-time heating mode
Press the 

TIMER

 key repeatedly, the preset  stop-heating icon 

 displays

Press the 

SET

 key to set the preset  stop-heating time

Press the 

SET

 key, how-to is the same as mode 3 of preset bath

Preset bath and preset stop-heating can be set simultaneously. Once the settings are activated, water heater will 

automatically start heating the water to reach the preset temperature before the preset On time based on the current 

time and preset time. In the time between On and Off, water heater is on real-time heating mode (once the water

 temperature drops 5 degree than the preset temperature, heating will be started again). The water heater will automatically 

stop heating when reaches the Off time.

 Note: If the Off time is within the execution time of preset bath, then the Water heater will first stop heating for 1min, then 

continue the heating till ON time.

2

1

3

3

Item

Unit

ES15V-P2

ES25V-P2

ES35V-P2

 Rated voltage

230

230

230

Rated frequency

Hz

50

50

50

Rated pressure

MPa

0.80

0.80

0.80

Power

W

1000/2000/3000

1000/2000/3000

1000/2000/3000

Net weight

kg

10

14

17

Rated temperature

o

C

75

75

75

Volume

L

15

25

35

Technical data 

·

 Packing list

Parameters

Remarks: 

1. The permitted error limit of net weight above is 

±

10%. 

2. The values for mixing factor, average temperature of hot water outlet, re-heating time 

(a temperature rise of 50°C) are all measured under the maximum power condition. 

Front 

view

Side 

view

Cutaway 

view

Rear 

view

b

 a

C

d

e

SPEED

SET

TIMER

Dimensions

Model

a

b

c

d

e

ES15V-P2

316mm

291mm

623mm

152mm

100mm

ES25V-P2

378mm

362mm

616mm

152mm

100mm

ES35V-P2

415mm

398mm

663mm

152mm

100mm

A

 Hot water outlet 

B

 Cold water inlet 

C

 Tank    

D

 Heating element    

E

 Anode rod

 F

 Thermometer tube  

G

 Wall-mounting bracket 

Remarks: 

The permitted error limit of above parameters is 

±

10%. 

Packing list

Electric 

water 

heater (Set)

Safety valve 

Drain hose 

(Unit)

Expansion 

hook 

(PCS)

User's 

manual 

(Copy)

Connecting 

line (PCS)

Remote control, 

Remote control 

unit holder (Set)

Accessories 

pack (Unit)

ES15V-P2

1

1

2

1

1

1

1

ES25V-P2

1

1

2

1

1

1

1

ES35V-P2

1

1

2

1

1

1

1

 

Name

Quantity
Model

(Figure 4)

Item

Unit

ES15V-P2

ES25V-P2

ES35V-P2

Waterproof grade

/

IPX4

IPX4

IPX4

Mixing factor

%

13

5

4

Tap water pressure

MPa

No less than 

0.05MPa

No less than 

0.05MPa

No less than 

0.05MPa

Average temperature of hot 

water outlet

o

C

64

68

64

Re-heating time 

(a temperature rise of 50

o

C)

min

14

21

41

Diameter of power wire

mm

2

3×1.5

3×1.5

3×1.5

SPEED

SET

TIMER

Отзывы: