6. Remove 6 screws that hold the motor bracket and
evaporator coil.
7. Lift the evaporator coil and remove the motor bracket.
8. Loosen the motor shaft set screw. Phillips head screw.
9. Unplug the motor from the circuit board.
10. Lift and slide the motor away from the blower wheel.
11. Remove the two black anti vibration mounts from the
defective motor and place them on the new motor.
12. Install new motor in reverse order.