WARNING

Please read these "Safety Precautions" first and then accurately execute the installation work.

Though the precautionary points indicated herein are divided under two headings,                       and                     , those

points which are related to the strong possibility of an installation done in error resulting in death or serious injury are

listed in the                     section. However, there is also a possibility of serious consequences in relationship to the

points listed in the                      section as well. In either case, important safety related information is indicated, so by all

means, properly observe all that is mentioned.

After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please

explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's

manual. Moreover, ask the customer to keep this sheet together with the owner's manual.

This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment

such as engineering shop could cause equipment malfunction.

Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects

from improper installations can be the cause of water leakage, electric shocks and fires.

Execute the installation accurately, based on following the installation manual. Again, improper installations can result

in water leakage, electric shocks and fires.

When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure

for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing

this countermeasure, consult with the company from which you purchased the equipment, and make the installation

accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is

the danger of a resultant oxygen deficiency accident.

For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient,

injury can result from a falling of the unit.

Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and

hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit.

For electrical work, please see that a licensed electrician executes the work while following the safety standards related

to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits

are used. Insufficient power source circuit capacity and defective installation execution can be the cause of electric

shocks and fires.

Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to

the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation

or fire.

Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can

also result in heat generation or fire.

When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated

refrigerant (R410A) within the refrigeration cycle. Rupture and injury caused by abnormal high pressure can result from

such mixing.

Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company

can result in water leakage, electric shock, fire and refrigerant leakage.

WARNING

CAUTION

Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground

wire. Improper placement of ground wires can result in electric shock.

The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing

an earth leakage breaker may result in electric shock.

Do not install the unit where there is a concern about leakage of combustible gas.

The rare event of leaked gas collecting around the unit could result in an outbreak of fire.

For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to

prevent condensation. Inadequate plumbing can result in water leakage and water damage to interior items.

CAUTION

WARNING

CAUTION

Precaution for Installation

13

Содержание ADH071M1ERG

Страница 1: ...d by qualified personnel Please read this manual carefully before installation Cautions Safety Precautions Parts and Functions Heating Mode Care and Maintenance Troubleshooting Accessories Precaution for Installation Is The Unit Installed Correctly Installation Procedure ADH105M1ERG ADH125M1ERG ADH140M1ERG ADH071M1ERG ADH071M3ERG ADH090M1ERG ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG 3 4 7 8 ...

Страница 2: ...gerant charge of the product see unit name plate C additional refrigerant amount charged in the field D total refrigerant charge E outdoor unit F refrigerant cylinder and manifold for charging IMPORTANT INFORMATION REGA RDING THE REFRIGERANT USED Haier Industrial Park Qianwangang Road Eco Tech Development Zone Qingdao 266555 Shandong P R C A B C D kg kg kg R410A WARNING If the supply cord is damag...

Страница 3: ... instructions set forth in the User s Guide Installation shall be done by professional people don t install unit by yourself For the purpose of safety the air conditioner must be properly grounded in accordance with specifications Always remember to unplug the air conditioner before opening inlet grill Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull ...

Страница 4: ...jury or death Installation by yourself is not encouraged because it could cause such problems as water leakage electrical shock or fire accident by some improper handing Installationbyyourselfisnotencouragedbecauseitcould cause such problems as water leakage electrical shock or fire accident by some improper handing Do not install nearby the place where may have leakage of flammable gas Depending ...

Страница 5: ...ture of the unit for any damage after a use of long period of time Insufficient ventilation could cause an oxygen deficiency accident If the structure is not repaired immediately the unit could topple down to cause a personal injury When cleaning the system stop the operation and turn off the power switch Do not put water containers on the unit such as a flower vase etc Cleaning should never be do...

Страница 6: ...ion Cut off the power supply to adjust the SW1 4 and SW1 5 or else the operation is invalid 10 2 For ADH071M3ERG ADH105M1ERG ADH125M1ERG ADH140M1ERG ADH105H1ERG ADH125H1ERG ADH140H1ERG ADH160H1ERG static pressure selection need achieved by wired controller refer wired controller s manual to get details SW1 1 2 3 4 5 6 7 8 Static pressure 10 Pa 30 Pa 50 Pa 70 Pa OFF OFF OFF ON ON OFF ON ON 6 Safety...

Страница 7: ...ADH160H1ERG ADH071M3ERG 7 Parts and Functions The pump drain opening Electrical components Case Drain pan Evaporator Air outlet frame Air outlet frame Drain pan Evaporator The pump drain opening Electrical components Case Air outlet frame Fan Drain pan The drain opening Electrical components Case ...

Страница 8: ...ver to ordinary heating operation Heat pump type warming With the heat pump type warming the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space is utilized Defrosting operation When a room is warmed with a heat pump type air conditioner frost accumulates on the heat exchanger of outdoor unit along with the drop of indoor temperature Si...

Страница 9: ... is consumed even the air conditioner is in stop Clean the air filter and set it in the place Care and Cleaning of the unit Clean with soft and dry cloth If it is very dirty dissolve neutral detergent in the lukewarm water and make the cloth wet with the water After wiping clean off the detergent using clean water 1 Clean the air filter by lightly tapping it or with the cleaner It is more effectiv...

Страница 10: ...the flowing sound of the refrigerant and it is not a trouble Water flowing sound is heard This is caused by heat expansion or contraction of plastics Cracking sound is heard It smells Air which blows out from the indoor unit sometimes smells The smell results from residents of tobacco smoke or cosmetics stuck inside of unit When the air conditioner is used at restaurant etc where dense edible oil ...

Страница 11: ...en or PCB hardware malfunction 0 12 0C Malfunction of drain system Pump motor disconnected or at wrong position or the float switch disconnected or at wrong position or the short circuit bridge disconnected 0 13 0D Zero cross signal wrong Zero cross signal detected wrong 0 14 0E Abnormal communication between main control PCB fan motor driver communication wire disconnected or wrong connected or P...

Страница 12: ... the wired remote control and electric control board 1 Accessories supplied with the indoor unit Accessories Wired controller For Air conditioner operation For tightening the Connecting pipe For indoor side pipe joint gas side For indoor side pipe joint liquid side 1 Drainage fittings group For ADHM series only 1 Air conditioner operation 7 For fixing the heat insulation For ADHH series only 4 For...

Страница 13: ...sult from a falling of the unit Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and hurricanes etc Improper installations can result in accidents due to a violent falling over of the unit For electrical work please see that a licensed electrician executes the work while following the safety standards related to electrical equipment and l...

Страница 14: ...The place where salt breeze blows Seaside etc The place where dense soot smoke exists The place where humidity is extraordinarily high The place where near the machine which radiates the electromagnetic wave The place where voltage variation is considerably large For details consult your sales dealer The electric work must be burden on the authorized engineer with qualification for electric work a...

Страница 15: ...tional panel etc depending on the specific type Select places for installation satisfying following conditions and at the same time obtain the consent on the part of your client user Places where chilled or heated air circulates freely When the installation height exceeds 3m warmed air stays close to the ceiling In such cases suggest your client users to install air circulators Places where perfec...

Страница 16: ...lightly lower Hanging bolt M10 nut Main unit M10 washer M10 spring washer 1 Preparation for suspending the unit a Size of hole at ceiling and position of hanging bolts b Hanger bolts installation Use care of the piping direction when the unit is installed Hanging bolt M10 Hole in anchor Hole in plug Insert Concrete Dimensions A mm B mm C mm Model Indoor Unit D mm E mm F mm 150 A B C Hanging bolt p...

Страница 17: ...onnection of the drain socket and drain hose accessory Drain hose Stage difference part Drain socket Drain socket Main unit VP field purchased Pipe cover large for insulation accessory VP field purchased Pipe cover for insulation field purchased Drain hose accessory Pipe cover small for insulation accessory Clamp accessory Adhesion Installation Procedure 17 Unit model The size of drain opening 32m...

Страница 18: ...tretch for the needed height is higher than 500 mm the back flow quantity of drain at the event of interruption of the operation gets too much and it may cause overflow at the drain pan Therefore make the height of the drain pipe within the distance given in the sketch below Right overhead Drain hose Joint for VP 25 Local procurement 600 Maximum local drain up dimension 290 325mm g Avoid positioni...

Страница 19: ...st Conduct a drainage test after completion of the electrical work During the trial make sure that drain flows properly through the piping and that no water leaks from connections In case of a new building conduct the test before it is furnished with the ceiling Be sure to conduct this test even when the unit is installed in the heating season Attached drain hose clamp Drain piping Main unit Drain...

Страница 20: ...connection Make wiring to supply power to the outdoor unit so that the power for the indoor unit is supplied by outdoor unit Item Model Phase Switch breaker A Circuit breaker Overcurrent protector rated capacity A Power source wire size minimum mm2 Switch breaker A Earth leakage breaker Leak current mA 30 1 40 30 6 0 40 Outdoor 3 phase type Outdoor unit terminal block Indoor unit terminal block Po...

Страница 21: ......

Страница 22: ......

Страница 23: ......

Страница 24: ...Address Haier Industrial Park Qianwangang Road Eco Tech Development Zone Qingdao 266555 Shandong P R C Contacts TEL 86 532 88936943 FAX 86 532 8893 6999 Website www haier com ...

Отзывы: