1. Switches or jumper wire must be adjusted when the wire controller is powered off. If the wire controller is
powered on, the above operations will be invalid.
2. Function difference between master wire controller and slave one:
Notes
Factory Setting
OFF
default setting
SW1-8
Installation Manual For Wire Controller
12
Query indoor malfunction history:
In the state of power on or power off, press [CHECK] button, enter the malfunction-querying mode of all indoor units in
the group. Then [CHECK] and [UNIT NO.] will display, and the actual indoor numbers will be displayed in some sequence
(unit number is in decimals). At the same time, in the time region, there will be the current malfunction and the latest time
malfunction, the displaying format is [XX:YY], in which XX stands for the current malfunction, if normal, it will display "--";
YY stands for the latest time malfunction. The failure code of every unit will display for 3 seconds. After the failure codes
of all indoor units in the whole group are displayed, the mode will quit automatically.
Operation
How to change the function switches?
Master wire
controller
Slave wire controller
Function
All of functions
Only with below functions: ON/OFF, MODE, FAN
SPEED, SET TEMP., SWING
Contrastive
items
No.
Type
State of switch
Function description
Select the master or
the slave controller
ON
set as the slave controller
OFF
SW1-1
OFF
set as the master controller
Select the controller
mode
ON
standard controller
SW1-2
air handler controller
Room temperature
display option
ON
visible room temperature
SW1-3
invisible room temperature
26
o
lock
ON
Unavailable 26
o
lock
SW1-4
available 26
o
lock
Temperature sensor
position option
ON
Sensor of the controller
SW1-5
Sensor in the unit
OFF
Auto restart
ON
unavailable
SW1-6
available
OFF
OFF
OFF
Factory Seting
ON
default setting
SW1-7
3.Wiring instruction
Use shielded wire between indoor and wire controller.And be earthed on one side, or the unit will not work normally
because of interference.
Note:
Confirm the terminal connection firmly, and do not get in tough with shielded wire.
4.Place wire controller on the holder, and pay attention not to pressing any wires.
10.45
Screw holes
5.3
Bracket
Wire controller
1. Take down wire controller from the holder
2. Install the controller holder
According to the position of 2 screw holes on the
holder, drill 2 holes on the wall, and strike the wood
stopper to the holes respectively.
Then align the 2 screw holes of wired controller
holder to the wood stopper, fix the holder on the wall
with wood screw.
Note:
Try a wall as flat as possible for installation.
Don't use excessive force to tighten screws,
otherwise, the holder will be damaged.
AUTO
FAN ONLY
COOL
DRY
HEAT
TES
FAN
AUTO
HIGH
LOW
FIX
CENTRAL
OPERATION
STANDBY
PRE-HEAT
DEFROST
FILTER
MODE
HEALTH
SWING
CHECK
UNIT NO.
C
F
DEMAND
CEN. ADD.
SYS. ADD.
MANUAL
ROOM TEMP.
SET TEMP.
TIMER
VENTILATION
CLOCK UP DOWN
ON
OFF
DAILY
AUTO
RECOVERY
NORMAL
MODE
FAN
SWING
HEALTH
CLOCK
TIMER
CHECK
FILTER
RESET
ON/OFF
SET
RECOVERY
TEMP
TIME
MED
Содержание AD09LS1ERA