background image

about 6 hrs

1 hr

1 hr

increase 1 C

increase 1 C

At night, before going to bed
you can press down the
SLEEP button on the controller
and the air-conditioner will run
by the comfortable sleeping
mode to make you sleep more
comfortable.

One hour after sleeping operation start, the temp. is 1 C higher than the setting one. After
another hour the temp. rises 1 C and then run continuously for another 6hrs' and then
close. The actual temp. is higher than the setting one which is to prevent from being too
cool to your sleep.

In cooling, dehumidifying mode

One hour after start up, the temp. decrease 2 C lower than the setting one. After another
hour decrease by more 2 C.
The temperature will automatically rise by 1 C after another 3hrs' operation, and then
automatically close after 3hrs' continuous operation. The actral temperature is lower than
the setting one which is to prevent from being too hot to your sleep.

In heating mode

SETTING T

SLEEP RUN BEGINS

SLEEP RUN STOPS

1 hr

1 hr

3 hrs

about 3 hrs

decrease 2 C

decreases 2 C

increase1 C

SHUT DOWN

SLEEP RUN STOPS

Heat  mode

SLEEP RUN BEGINS

SETTING T

SHUT DOWN

Cooling  mode

Comfortable Sleep

Note:
    In AUTO mode, unit will run in SLEEP function according to the operation mode.
    After setting SLEEP function, it is forbidden to calibrate clock.
    If the set sleep-time does not reach 8 hours, the unit will stop operation automatically
after set time is complete.
    Set "TIMER-OFF" function first, then set SLEEP, and the sleep-set is performance; set
TIMER-ON function first, the sleep function can only be set before TIMER-ON; if set
theSLEEP function first, the TIMER function can not be set.

Press SLEEP button once to make the air conditioner have the previous-set sleep time
(first power-on is "1h"), the sleep symbol will appear. Press time button      /    , you can
choose the time in 1~8 hours. Each press of     /    , the time increases/reduces 1 hour
and "xh" appears in the humidity setting part, "OFF" appears in "TIMER OFF" display part
and timer-off time; press SLEEP button again to cancel sleep function, the sleep symbol
diappears.

MODE

FAN

SWING

TEMP

CLOCK

SET

TIMER

SLEEP

RESET

FILTER 

RESET

ON/OFF

A

M

S

E

T

O

F

F

GUIDE TO OPERATION

11

A

M

Содержание AB182ACBDA

Страница 1: ...OPERATION MANUAL No 0010571994 CASSETTE AIR CONDITIONER AB182ACBDA AU182AFBAA HBU 18HD03 R1 ...

Страница 2: ...T AND ITS FUNCTION INTRODUCTION TO SPARE PARTS GUIDE TO OPERATION AIR FLOW DIRECTION ADJUSTMENT PROCEDURE REMOTE CONTROL AND MALFUNCTION JUDGEMENT FOR COMFORTABLE USE CARE AND MAINTENANCE WARNING OPERATION 2 3 4 5 6 7 11 12 13 14 15 17 18 22 ...

Страница 3: ...l the packaging materials employed in the package of your new air conditioner may be disposed without any danger to the environment Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal services nearest to your house Safety Instructions and Warnings Before starting the air conditioner read the information given in the User s Guid...

Страница 4: ...ust be properly grounded in accordance with specifications Always remember to unplug the air conditioner before opening inlet grill Never unplug your air conditioner by pulling on the power cord Always grip plug firmly and pull straight out from the outlet Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User s Guide Installation ...

Страница 5: ...om here Air flow direction is adjusted Air inlet grille Takes in the indoor air Air filter Removes dust or dirt out of the inlet air In the Air inlet grille Air inlet Outdoor unit Air outlet Compressor inside of unit 4 THE NAME OF EACH PART AND ITS FUNCTION ...

Страница 6: ...s with those displayed in actual operation CLOCK Used to set correct time TIMER Used to select TIMER ON TIMER OFF TIMER ON OFF TIME Used to set clock and timer setting Used for unit start and stop Power ON OFF MODE Used to select AUTO RUN COOL DRY HEAT and FAN operation FAN SPEED Used to select fan speed LO MED HI AUTO TEMP Used to select your desired temp SET Used to confirm Timer and Clock setti...

Страница 7: ... set When unit is started for the first time clock should be adjusted as follows Press CLOCK button AM or PM flashes Press or to set correct time Each press will increase or decrease 1min If the button is kept depressed time will change quickly After time setting is confirmed press SET AM and PM stop flashing while clock starts working Operation Remote control SLEEP ...

Страница 8: ...peration mode To run it next time just select the operation mode and it will start with the previous setting No reselecting is needed TIMER ON OFF needs reselecting In FAN mode temp can t be set Hints For cooling only type no HEAT function AUTO COO DR FA The air conditioner has the function of POWER FAILURE RESUME HEA 3 Fan Press FAN button For each press fan speed changes as follows Unit will run...

Страница 9: ...p setting decreases 1 C If button is kept depressed temp setting will decrease quickly Recommendations Hints Wire controller can memorize each operation status When starting it next time just press ON OFF button and unit will run in previous status Press FAN button For each press fan speed changes as follows 4 Fan speed Unit runs at the speed displayed on LCD In HEAT mode warm air will blow out af...

Страница 10: ...f button is kept depressed time will change quickly Every time the button is pressed time decreases 10min If button is kept depressed time will change quickly Time will be shown on LCD It can be adjusted within 24hours 4 Confirming your After setting correct time press SET button to confirm ON or OFF stops flashing Time displayed Unit starts or stops at x hour x min ON or OFF Timer mode indicator ...

Страница 11: ...sted within 24hours AM refers to morning and PM to afternoon Time displayed Unit starts at Xhour X min After time setting press TIMER button to confirm ON stops blinking While OFF starts blinking 4 Time confirming for TIMER ON Follow the same procedures in Time setting for TIMER ON 6 Time confirming for TIMER OFF After time setting press SET button to confirm OFF stops flashing Time displayed Unit...

Страница 12: ... s about 3 hrs decrease2C decreases2C increase1C SHUTDOWN SLEEP RUN STOPS Heat mode SLEEPRUNBEGINS SETTINGT SHUTDOWN Cooling mode Comfortable Sleep Note In AUTO mode unit will run in SLEEP function according to the operation mode After setting SLEEP function it is forbidden to calibrate clock If the set sleep time does not reach 8 hours the unit will stop operation after set time is complete Set T...

Страница 13: ...er stopped Change to the AIRFLOW mode SWING LOUVER STOPPED Louver moves in upward and downwarddirections continuously When the LOUVER button is pushed during SWING mode it stops swinging at the just angle Avoid direct air flow to the body for many hours Avoid downward blowing operation of cooling mode for many hours Do not touch the swing louver during swing operation CAUTION AIR FLOW DIRECTION AD...

Страница 14: ...king afte the power after the power failure compensation is set if the air conditioner will not be used for a long time please cut off the power supply to prevent its operation from being resume after the power is supplied again or press the Switch On Off button after the power comes again After the power failure compensation is set if power failure suddenly occurs while the air conditioner is wor...

Страница 15: ...iling it is recommended to use the circulator For details contact your dealer 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person An extend cord is not recommended the requirement of the power supply cord is H07RN F 3G 2 5mm2 suitable for installation in European region 3 If the fuse on PC board is broken please change it with ...

Страница 16: ... to clean the air filter with water 2 How to remove the filter Hold the hook part with fingers asillustrated below twopositionsatleftandright atlowerpartoffil ter and pull toward this side while slightly pushing upward 2 After drying the air filter set it up on the air conditioner If the air filter is very dirty dissolve neutral detergent in the lukewarm water approx 30 C rinse the air filter in t...

Страница 17: ...llumination Isn t the earth leakage breaker in action I t i s d a n g e r o u s T u r n o f f t h e p o w e r s u p p l y s w i t c h i m m e d i a t e l y a n d c o n t a c t t h e s a l e s dealer Cooling or heating is not sufficient Is the themostat adjust as required Isn ttheairfilterdirty Isn t any doors or window left opened Doesn t any obstacle exist at the air inlet or outlet Isn t the swi...

Страница 18: ...m the outdoor unit during heating U n i t d o e s n o t s t a r t d e f r o s t i n g o p e r a t i o n W a i t f o r three m i n u t e s When the air conditioner is used at restaurant etc where dense edible oil fume is always exists white fog sometimes blows out of air outlet during operation In this case consult sales dealer for cleaning the heat exchanger To prevent frost from being accumulated...

Страница 19: ...to start the operation a little earlier in a very cold morning IS THE UNIT INSTALLED CORRECTLY Confirm the following items for safe and comfortable use of air conditioner The installation work is to be burden on the sales dealer and do not conduct it by yourself Installation place Avoid installing the air conditioner near the place where possibility of in flammable gas leakage exists Install the u...

Страница 20: ...aker should be installed This is necessary to prevent electric shock The unit must be grounded CAUTIONS FOR INSTALLATION When you have read through the manual keep it always at hand for ready consultation If the opera tor is replaced make sure to hand over this manual to the new operator Strictly prohibited Observe instructions faithfully Provide a positive grounding WARNING The system should be a...

Страница 21: ... ground ed Bodily injury could result by a col lapse Bodilyinjurycouldresultbyacareless installation Grounding cable should never be con nected to a gas pipe city water pipe lightning conductor rod or grounding cable of telephone If the grounding cableisnotsetproperly itcouldcause electric shocks You should refrain from exposing your body directly to cool wind for a long time Do not poke the air i...

Страница 22: ...ould cause electric shocks Do not install the system where the wind of blower reaches di rectly the flora and fauna Make sure to use a fuse of prop er electric rating Itwillnotbegoodfortheirhealth Use of steel or copper wire in place of afuseisstrictlyprohibitedbecauseit could result in a trouble or fire acci dent Neither stand on the air condi tioner nor place something on it There are risks of f...

Страница 23: ...CAUTION 22 ...

Отзывы: