Indoor unit

2.Another way for the models of 18,22 ,24,as illustrated:

Way One (right direction): Take off the lid for right piping pipe,put the Outlet joint into the lid,then put the fresh air tube
                                              into the outlet jont.
Way Two (left direction): Take off the lid for leftt piping pipe,put the Outlet joint into the lid,then put the fresh air tube
                                           into the outlet jont.

5.Installation instruction on the indoor part of the fresh air device

To indoor unit

To outdoor fresh air motor

The connecting method of
 fresh air box signal wire

1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar
   qualified person. The type of connecting wire is H05/07RN-F or 245IEC57(YZW).
2. If the fuse on PC board is broken please change it with the type of T. 3.15A/250V.
3. The wiring method should be in line with the local wiring standard.
4. After installation, the power plug should be easily reached.

5

For the units with
fresh air function

HSU-22C03/V(ZXF)
HSU-22C03/V(ZF)
HSU-24C03/V(ZXF)

3G2.5mm

2

HSU-24C03/V(ZF)

Indoor unit

Outdoor unit

)

L(

1

)

N(

2

HSU-18H03/V(ZXF)
HSU-22H03/V(ZXF)

1.Two ways for the installation of indoor part, as illustrated:

Way One:(For all the models)
In the guard ring, connect outlet joint with the fresh air tube .
Way Two(Only for the models of 09,12):
Insert the joint of water collecting pan into the fresh air tube, then connect the other end of joint
with mesh enclosure of water collecting pan.

Installation way One

Installation way Two

Fresh air tube

Outlet joint
(in guard ring)

Guard ring

Joint of water
collecting pan Fresh air tube

HSU-22H03/V(ZF)

HSU-12H03/V(ZXF)

HSU-12H03/VB(ZXF)

HSU-24H03/V(ZXF)
HSU-24H03/V(ZF)

Indoor unit

Outdoor unit

HSU-09C03/VA(ZXF)
HSU-12C03/VA(ZXF)

HSU-09H03/VA(ZXF)
HSU-12H03/VA(ZXF)

Indoor unit

Outdoor unit

3G1.0mm

2

5G1.0mm

2

3G2.5mm

2

Indoor unit

Outdoor unit

)

L(

1)

N(

2

HSU-18C03/V(ZXF)

Connecting wiring
-mod 12: 5G1.0mm

2

-mod 18-22-24:
 3G2.5mm

2

+2x0.75mm

2

Power cable:
-mod 09-12:

3G1.0mm

2

-mod 22-24:

3G2.5mm

2

HSU-24HK0307

Lid for left piping

Fix with adhesive tape

Lid for under piping

Outlet joint

Drain hose

 Change for fresh air tube

Indoor unit

Outdoor unit

)

L(

1)

N(

2

Connecting wiring

˖

Connecting wiring

˖

Connecting wiring

˖

Connecting wiring

˖

-mod 18:

3G1.5mm

2

HSU-24HD0307

Содержание 0010554405B

Страница 1: ... of piping directions Rear left Rear right Left Below Right Connecting electric cable for indoor and outdoor Drain hose Heating insulating material 4X50 4X25 Piping hole cover Read this manual before installation 1 Driver 2 Hacksaw 3 Hole core drill 4 Spanner 17 19 and 26mm 5 Torque wrench 17mm 22mm 26mm 6 Pipe cutter 7 Flaring tool 8 Knife 9 Nipper 12 Reamer 10 Gas leakage detector or soap and wa...

Страница 2: ... is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where a distance marked is available as illustrated in the above figure Before inserting power plug into receptacle check the voltage without fail The power source is the same as the corresponding name plate Ins...

Страница 3: ...Refer to the previous article When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a hole of 70 mm in diameter slightly descending to outside the wall Install piping hole cover and seal it off with putty after installation Section of wall hole Piping hole pipe...

Страница 4: ... outside the room cable into left side of the wall hole in which the pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop signal wire Change for fresh air tube 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then ...

Страница 5: ...5mm2 HSU 24C03 V ZF Indoor unit Outdoor unit L 1 N 2 HSU 18H03 V ZXF HSU 22H03 V ZXF 1 Two ways for the installation of indoor part as illustrated Way One For all the models In the guard ring connect outlet joint with the fresh air tube Way Two Only for the models of 09 12 Insert the joint of water collecting pan into the fresh air tube then connect the other end of joint with mesh enclosure of wa...

Страница 6: ...d cause a leakage of gas Pipe Diameter Liquid side 6 35mm 1 4 Gas side 9 52mm 3 8 Fastening torque Drawing for the installation of indoor and outdoor units Insert the cable according to terminal number in the same manner as the indoor unit Fix the cable with a clamp 18N m 40N m Half union Flare nut Spanner Torque wrench 6 Gas side 12 7mm 1 2 50N m 6 Easily demount cleaning of indoor unit 1 Top inl...

Страница 7: ...nding piping air inside piping shall be removed by using external refrigerant gas charge according to the following list Brand new outdoor unit is charged 50g or 80g 22k 24k more refrigerant than regulated weight Only for first installation this extra 50g or 80g 22k 24k can be used to purge airin pipes During this procedure 50g or 80g 22k 24k refrigerant will be discharged in piping This must be s...

Страница 8: ...n pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to operate through the instruction manual Gas leak from pipe connecting Heat insulation of pipe connecting Are the connecting wirings of indoor and outdoor firmly inserted to ...

Отзывы: