No.0010554405

B

Installation Manual of Room Air Conditioner

No.

Accessory parts

Remote controller

R-03 dry battery

Mounting plate

Drain hose

Steel nail, cement

Screw

Plastic cap

Drain-elbow

Cover

Cushion

Connecting cable

1

1

A

B

C

D

E

F

G

2

3

4

5

6

7

8

9

10

2

1

1

6

4

1

1

4

1

Number
    of
articles

Accessory parts

Optional parts for piping

Mark

Parts name

more than 5cm

more than 10cm

more than 60cm

more than 15cm

Non-adhesive tape

The marks from     to     in the figure are the parts numbers.

The distance between the indoor unit and the floor should
be more than 2m.

more than 10cm

more than 10cm

more than 10cm

Adhesive tape

Saddle(L.S) with screws

Attention must be paid to
the rising up of drain hose

Arrangement of piping directions

Rear left

Rear

right

Left

Below

Right

Connecting electric cable
for indoor and outdoor

Drain hose

Heating insulating material

4X50

4X25

Piping hole cover

Read this manual before installation

1.Driver
2.Hacksaw
3.Hole core drill
4.Spanner(17,19 and 26mm)

5.Torque wrench(17mm,22mm,26mm)
6.Pipe cutter
7.Flaring tool
8.Knife

9.Nipper

12.Reamer

10.Gas leakage detector or
     soap-and-water solution
11.Measuring tape

Explain sufficiently the operating means to the user
according to this manual.

A

G

 Change for
 fresh air box

 Change for
fresh air
tube(suit)

Outlet joint

11

12

13

1

1

2

Screw

6

G

F

A

C

D

E

13

12

Note:1.Cooling only units don't have Drain-elbow

Outlet joint

1

2.       is only for the models of 18,22.
3.The models ZF don't have fresh function
    and accessory parts related with freshing.

Drawing for the installation of indoor and outdoor units

Necessary Tools for Installation

15

14

14

Содержание 0010554405B

Страница 1: ... of piping directions Rear left Rear right Left Below Right Connecting electric cable for indoor and outdoor Drain hose Heating insulating material 4X50 4X25 Piping hole cover Read this manual before installation 1 Driver 2 Hacksaw 3 Hole core drill 4 Spanner 17 19 and 26mm 5 Torque wrench 17mm 22mm 26mm 6 Pipe cutter 7 Flaring tool 8 Knife 9 Nipper 12 Reamer 10 Gas leakage detector or soap and wa...

Страница 2: ... is sufficiently ventilated Place possible to bear the unit where vibration and noise are not increased Place where discharged wind and noise do not cause a nuisance to the neighbors Place where a distance marked is available as illustrated in the above figure Before inserting power plug into receptacle check the voltage without fail The power source is the same as the corresponding name plate Ins...

Страница 3: ...Refer to the previous article When the mounting plate is first fixed for the position of wall hole Fix to side bar and lintel a mounting bar Which is separately sold and then fasten the plate to the fixed mounting bar Make a hole of 70 mm in diameter slightly descending to outside the wall Install piping hole cover and seal it off with putty after installation Section of wall hole Piping hole pipe...

Страница 4: ... outside the room cable into left side of the wall hole in which the pipe has already existed 2 Pull out the cable on the front side and connect the cable making a loop signal wire Change for fresh air tube 1 Insert the drain hose into the dent of heat insulation materials of indoor unit 2 Insert the indoor outdoor electric cable from backside of indoor unit and pull it out on the front side then ...

Страница 5: ...5mm2 HSU 24C03 V ZF Indoor unit Outdoor unit L 1 N 2 HSU 18H03 V ZXF HSU 22H03 V ZXF 1 Two ways for the installation of indoor part as illustrated Way One For all the models In the guard ring connect outlet joint with the fresh air tube Way Two Only for the models of 09 12 Insert the joint of water collecting pan into the fresh air tube then connect the other end of joint with mesh enclosure of wa...

Страница 6: ...d cause a leakage of gas Pipe Diameter Liquid side 6 35mm 1 4 Gas side 9 52mm 3 8 Fastening torque Drawing for the installation of indoor and outdoor units Insert the cable according to terminal number in the same manner as the indoor unit Fix the cable with a clamp 18N m 40N m Half union Flare nut Spanner Torque wrench 6 Gas side 12 7mm 1 2 50N m 6 Easily demount cleaning of indoor unit 1 Top inl...

Страница 7: ...nding piping air inside piping shall be removed by using external refrigerant gas charge according to the following list Brand new outdoor unit is charged 50g or 80g 22k 24k more refrigerant than regulated weight Only for first installation this extra 50g or 80g 22k 24k can be used to purge airin pipes During this procedure 50g or 80g 22k 24k refrigerant will be discharged in piping This must be s...

Страница 8: ...n pan of the indoor unit and confirm that drainage is carried out surely to outdoor In case that the attached drain hose is in a room please apply heat insulation to it without fail Please kindly explain to our customers how to operate through the instruction manual Gas leak from pipe connecting Heat insulation of pipe connecting Are the connecting wirings of indoor and outdoor firmly inserted to ...

Отзывы: