.3.7 The communication fault between IPM and outdoor PCB
Outdoor display: LED1 flash 4 times
Method of Communication is detected by checking the IPM module and the outdoor PCB
Malfunction
Detection
Malfunction
■
The outdoor PCB broken leads to communication fault
Decision
■
The IPM module broken leads to communication fault
Conditions
Supposed
■
The outdoor PCB is broken
Causes
■
The IPM module is broken
■
Communication wiring disconnected
Troubleshooting * Caution Be sure to turn off power switch before connect or disconnect connector, or
else parts damage may be occurred.
1) Check whether plug of MODULE COM and MODULE POWER on the outdoor
PCB and IPM module is tight connected
2) Check whether the connection of P & N wire between IPM and outdoor is tight
Is the connection OK?
1.Check whether the voltage between 1
and 2 of Module Power
is about DC5V,
2.Check whether the voltage between2
and 3 of Module Power is about DC15V,
Replace outdoor PCB
Replace power module
YES
NO
NO
YES
Malfunction unsolved
1) Pull out and reinsert the terminals.
2) Replace connected wire
Seivice diagnosis
Domestic air conditioner
37
Содержание 1U35QA1ERA
Страница 11: ...Pinping diagrams Domestic air conditioner 4 Pinping diagrams 9 EXV EXV ...
Страница 12: ...Operation range Domestic air conditioner 5 Operation range 10 10 0 20 16 32 10 20 15 ...
Страница 15: ...Connector Wiring Diagram Domestic Air Conditioner 13 PCB 2 12K CN2 CN3 CN4 CN5 CN6 CN7 CN11 CN10 CN1 CN8 CN9 ...
Страница 16: ...Functions and control Domestic air conditioner Wiring diagrams 14 OUTDOOR WIRING DIAGRAM 0010581667 80 ...
Страница 57: ...Circuit diagrams Domestic air conditioner 13 2 Module board Circuit Diagram 55 ...